4.3 Article

Feasibility and safety of a new dedicated biliary stent for EUS-guided hepaticogastrostomy: The FIT study (with video)

Journal

ENDOSCOPIC ULTRASOUND
Volume 12, Issue 1, Pages 59-+

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.4103/EUS-D-22-00023

Keywords

Biliary tract; intervention EUS; pancreatobiliary

Ask authors/readers for more resources

This study aimed to evaluate the feasibility and efficacy of EUS-HGS using a new dedicated stent with anti-migratory systems. The results showed that technical success was achieved in all patients without any stent misplacement or migration. The clinical success rate was 91% with no related deaths. Therefore, the use of this new stent can prevent stent migration and misplacement, and has a positive impact on preventing postoperative complications.
Background and Objectives: EUS-guided biliary drainage (BD) through hepaticogastrostomy (HGS) is an option in case of ERCP failure. Available data suggest that this procedure may be challenging with possible severe adverse events (AEs) mainly due to stent migration. The aim of our pilot study was to prospectively assess the technical and clinical outcomes of EUS-HGS using a new dedicated partially covered self-expandable metal stent with anti-migratory systems. Methods: This is a single-center prospective study enrolling patients with malignant biliary obstruction undergoing EUS-HGS after failed ERCP, between June 2020 and March 2021. The primary endpoint was the technical success rate. Evaluation of specific stent-related technical features as compared with commonly used self-expandable metal stent, clinical success rate, and procedure-related AEs was also assessed. Results: Twenty-two patients (15%-68.2%, female; mean age, 66.0 +/- 10.0) were enrolled in the study analysis. Different causes of ERCP failure were infiltration of papilla by neoplastic tissue (4, 18.2%), unreachable papilla for duodenal stricture (9, 40.9%), surgically altered anatomy with Roux-en-Y reconstruction (4, 18.2%), and incomplete BD after transpapillary stent placement (5, 22.7%). Technical success was achieved in all patients, in a mean procedural time of 43.3 +/- 26.8 min. Technical features were graded as high or medium in all cases. The clinical success rate was 91% (20/22, mean follow-up: 10.8 +/- 3.1 months). There were no cases of stent misplacement or stent migration. Three (13.6%) cases of a hepatic abscess requiring percutaneous drainage and systemic antibiotics were reported, with no impact on clinical success and following oncologic treatments. No deaths occurred. Conclusion: EUS-HGS with a new dedicated stent with anti-migratory systems is feasible and effective, preventing stent migration, and misplacement. Althoughthe persistent procedural challenges, dedicated devices may contribute to outcomes improvement and procedure diffusion

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available