4.6 Article

A Noninvasive Sweat Glucose Biosensor Based on Glucose Oxidase/Multiwalled Carbon Nanotubes/Ferrocene-Polyaniline Film/Cu Electrodes

Journal

MICROMACHINES
Volume 13, Issue 12, Pages -

Publisher

MDPI
DOI: 10.3390/mi13122142

Keywords

sweat glucose; biosensor; enzyme-based electrode; noninvasive detection; electrochemical method

Funding

  1. Fund of National Engineering Laboratory/Provincial Key Laboratory of food Science Discipline, Henan University of Technology [NL2021011, PL2018004]
  2. Innovative Funds Plan of Henan University of Technology [2020ZKJC27]
  3. Basic Research and applied basic research special funds
  4. Young Key Teachers Training Program of Henan University of Technology
  5. Henan Province scholarship program for Overseas Students

Ask authors/readers for more resources

Diabetes is a major threat to human health, and current detection methods are invasive, cumbersome, and time-consuming. In this study, a novel noninvasive and low-cost biosensor based on enzyme-based electrodes was proposed to detect glucose in human sweat for point-of-care use. Experimental results showed that the electrode had a short response time and a strong correlation.
Diabetes remains a great threat to human beings' health and its world prevalence is projected to reach 9.9% by 2045. At present, the detection methods used are often invasive, cumbersome and time-consuming, thus increasing the burden on patients. In this paper, we propose a novel noninvasive and low-cost biosensor capable of detecting glucose in human sweat using enzyme-based electrodes for point-of-care uses. Specifically, an electrochemical method is applied for detection and the electrodes are covered with multilayered films including ferrocene-polyaniline (F-P), multi-walled carbon nanotubes (MWCNTs) and glucose oxidase (GOx) on Cu substrates (GOx/MWCNTs/F-P/Cu). The coated layers enhance the immobilization of GOx, increase the conductivity of the anode and improve the electrochemical properties of the electrode. Compared with the Cu electrode and the F-P/Cu electrode, a maximum peak current is obtained when the MWCNTs/F-P/Cu electrode is applied. We also study its current response by cyclic voltammetry (CV) at different concentrations (0-2.0 mM) of glucose solution. The best current response is obtained at 0.25 V using chronoamperometry. The effective working lifetime of an electrode is up to 8 days. Finally, to demonstrate the capability of the electrode, a portable, miniaturized and integrated detection device based on the GOx/MWCNTs/F-P/Cu electrode is developed. The results exhibit a short response time of 5 s and a correlation coefficient R-2 of 0.9847 between the response current of sweat with blood glucose concentration. The LOD is of 0.081 mM and the reproducibility achieved in terms of RSD is 3.55%. The sweat glucose sensor is noninvasive and point-of-care, which shows great development potential in the health examination and monitoring field.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available