4.5 Article

Expansion of the application domain of a macromolecular ocular irritation test (OptiSafeTM)

Related references

Note: Only part of the references are listed.
Article Toxicology

Comparison of the different protocols of the Hen's Egg Test-Chorioallantoic Membrane (HET-CAM) by evaluating the eye irritation potential of surfactants

Luciana Madureira de Araujo Lowndes Viera et al.

Summary: HET-CAM is an alternative method for assessing eye irritation potential, aiming to quantitatively evaluate the effects of chemical substances on the chorioallantoic membrane surrounding a chicken embryo in an egg. Comparison of French and German HET-CAM protocols led to the optimization of the French protocol with reduced subjectivity. The results obtained from the two protocols showed no significant differences.

TOXICOLOGY IN VITRO (2022)

Article Toxicology

Validation of the SkinEthic HCE Time-to-Toxicity test method for eye hazard classification of chemicals according to UN GHS

N. Alepee et al.

Summary: This study examines the reproducibility of a TTT approach for chemicals utilizing the SkinEthicTM HCE tissue construct. The method is capable of accurately distinguishing between different classifications of chemicals. The results demonstrate high accuracy in both liquid and solid tests, and the predictive capacity of the method has been validated.

TOXICOLOGY IN VITRO (2022)

Article Toxicology

Ascorbic acid specifically reduces the misclassification of nonirritating reactive chemicals in the OptiSafe™ macromolecular eye irritation test

Stewart Lebrun et al.

Summary: The purpose of this study was to investigate whether the addition of ascorbic acid can reduce false-positive results for chemicals with reactive chemistries and whether it interferes with the detection of true-positive and true-negative ocular irritants. The results showed that ascorbic acid can significantly reduce false-positive results for chemicals with reactive chemistries, without affecting the detection of true-positive and true-negative chemicals.

TOXICOLOGY IN VITRO (2022)

Article Toxicology

Modeling the antioxidant properties of the eye reduces the false-positive rate of a nonanimal eye irritation test (OptiSafe)

Stewart J. Lebrun et al.

Summary: The addition of tear antioxidants to in vitro alternative test systems can substantially reduce the false-positive rate and improve ocular irritant detection.

TOXICOLOGY IN VITRO (2021)

Review Toxicology

Same-chemical comparison of nonanimal eye irritation test methods: Bovine corneal opacity and permeability, EpiOcular™, isolated chicken eye, ocular Irritection®, OptiSafe™, and short time exposure

Stewart Lebrun et al.

Summary: Testing and classification of chemicals for ocular effects is essential for safety guidelines. Analyzing the same chemicals showed a wide range in false-positive rates for different tests. While tiered testing strategies can reduce false positives, they may result in higher false negative rates with minimal improvement in accuracy.

TOXICOLOGY IN VITRO (2021)

Article Toxicology

SkinEthic HCE Time-to-Toxicity on solids: A test method for distinguishing chemicals inducing serious eye damage, eye irritation and not requiring classification and labelling

Nathalie Alepee et al.

Summary: This study developed a Time-to-Toxicity approach for solids based on SkinEthic™ HCE tissue construct, which can distinguish chemicals for eye irritation effectively. The method showed high reproducibility and accuracy in classifying chemicals based on their eye irritation potential.

TOXICOLOGY IN VITRO (2021)

Article Ophthalmology

Validation of the OptiSafe™ eye irritation test

Neepa Choksi et al.

CUTANEOUS AND OCULAR TOXICOLOGY (2020)

Article Medicine, Research & Experimental

The Ex Vivo Eye Irritation Test as an Alternative Test Method for Serious Eye Damage/Eye Irritation

Felix Spoeler et al.

ATLA-ALTERNATIVES TO LABORATORY ANIMALS (2015)

Editorial Material Toxicology

Alternatives to animal testing: current status and future perspectives

Manfred Liebsch et al.

ARCHIVES OF TOXICOLOGY (2011)

Article Biophysics

Cytosensor® Microphysiometer:: technology and recent applications

F Hafner

BIOSENSORS & BIOELECTRONICS (2000)