4.6 Article

Validation of combined carcinoembryonic antigen and glucose testing in pancreatic cyst fluid to differentiate mucinous from non-mucinous cysts

Journal

Publisher

SPRINGER
DOI: 10.1007/s00464-022-09822-6

Keywords

Pancreatic cystic neoplasms; Pancreatic cyst fluid; Carcinoembryonic antigen (CEA); Glucose; Diagnostic accuracy; Hepatobiliary tract and spleen; Endoscopy; Endoscopic ultrasound diagnostic and therapeutic

Categories

Ask authors/readers for more resources

This study assessed the value of combined CEA and glucose testing in pancreatic cyst fluid, and found that this method has high specificity and sensitivity for differentiating mucinous from non-mucinous pancreatic cystic neoplasms.
Background More accurate diagnosis of mucinous cysts will reduce the risk of unnecessary pancreatic surgery. Carcinoembryonic antigen (CEA) and glucose in pancreatic cyst fluid (PCF) can differentiate mucinous from non-mucinous pancreatic cystic neoplasms (PCN). The current study assessed the value of combined CEA and glucose testing in PCF. Methods Cross-sectional validation study including prospectively collected PCF from patients undergoing endoscopic ultrasonography-guided fine-needle aspiration (EUS-FNA) and pancreatic surgery. We performed laboratory measurements for CEA and glucose and measured glucose levels by a hand glucometer. Primary outcome was diagnostic accuracy evaluated by receiver operator curves (ROC), sensitivity, specificity, positive, and negative predictive value (PPV, NPV). Results Overall, PCF was collected from 63 patients, including 33 (52%) with mucinous and 30 (48%) with non-mucinous PCN. Histopathology (n = 36; 57%), cytopathology (n = 2; 3%), or clinical and/or radiological diagnosis (n = 25; 40%) was used as reference standard. Combined CEA (cut-off >= 192 ng/ml) and laboratory glucose testing (cut-off < 50 mg/dL) reached 92% specificity and 48% sensitivity, whereas either positive CEA (cut-off >= 20 ng/ml) or glucose testing (cut-off < 50 mg/ dL) showed 97% sensitivity and 50% specificity. Sensitivity and specificity were 80% and 68% for CEA >= 20 ng/mL versus 50% and 93% for CEA >= 192 ng/mL (the conventional cut-off level). Laboratory and glucometer glucose both reached 100% sensitivity and 60% and 45% specificity, respectively. None of the biomarkers and cut-offs reached a PPV exceeding 90%, whereas both glucose measurements had a NPV of 100% (i.e., high glucose excludes a mucinous cyst). Conclusion Combined CEA and glucose testing in PCF reached high specificity and sensitivity for differentiating mucinous from non-mucinous PCN. Glucose testing, whether alone or combined with the new CEA cut-off (>= 20 ng/mL), reached > 95% sensitivity for mucinous cysts, whereas only glucose reached a NPV > 95%.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available