4.7 Article

Simultaneous multi-measurand analyses of cross-linking reactions within a differential scanning calorimeter using optical fibre sensors

Journal

SENSORS AND ACTUATORS A-PHYSICAL
Volume 350, Issue -, Pages -

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.sna.2022.114101

Keywords

Fresnel reflection sensor; Cure monitoring; FTIR spectroscopy; Cross-linking; Hyphenated analytical equipment; DSC; Tg

Ask authors/readers for more resources

This paper presents the design and implementation of a multi-measurand fibre-optic probe for a differential scanning calorimeter. The probe consists of a disposable cleaved-end optical fibre as a Fresnel reflection sensor and an array of noncontact optical fibres for acquiring FTIR spectra. The results show excellent correlation between the data obtained from the calorimeter and the optical techniques.
The cross-correlation of cross-linking kinetic data obtained from different analytical equipment is not straightforward because the experimental conditions are seldom identical (temperature gradient, mass of the sample and substrate containing the analyte). Furthermore, the measurement principles can also be different (thermal, optical, rheological, etc). This paper reports on the design and implementation of a multi-measurand fibre-optic probe within a differential scanning calorimeter. The probe consisted of two components: (i) a low-cost and disposable cleaved-end of an optical fibre that served as a Fresnel refection sensor; and (ii) an array of noncontact optical fibres that enabled FTIR spectra to be acquired from within the calorimeter. The Fresnel reflection sensor was used as an immersion device to infer the evolution of the refractive index during the crosslinking of an epoxy/amine thermosetting resin. The array of optical fibres enabled FTIR spectra to be acquired during the cross-linking of the thermosetting resin. The motivation for developing this capability was to demonstrate cross-correlation between the quantitative FTIR spectral data, the qualitative Fresnel reflection sensor and the output from the differential scanning calorimeter. The cross-linking kinetics were determined for the two optical techniques and an excellent correlation was found between them and the data obtained from the calorimeter. The feasibility of using the same Fresnel reflection sensor, after cross-lining of the resin, for detecting the glass transition temperature was demonstrated.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available