4.6 Article

Simplified Nonlinear Current-Mode Control of DC-DC Cuk Converter for Low-Cost Industrial Applications

Journal

SENSORS
Volume 23, Issue 3, Pages -

Publisher

MDPI
DOI: 10.3390/s23031462

Keywords

analog control circuit; constant switching frequency; DC-DC Cuk converter; simplified nonlinear control; sliding-mode current control

Ask authors/readers for more resources

This paper presents a robust nonlinear current-mode control approach for a pulse-width modulated DC-DC Cuk converter in a simple analog form. The proposed controller does not require output capacitor current sensor and double proportional-integral compensators, minimizing the cost and complexity without degrading control performance. The simplified nonlinear controller rejects large disturbances, provides fast transient response, and maintains constant switching frequency. The proposed control methodology is verified through simulation, showing robust tracking performance, low percentage overshoot, fast transient response, and wide operating range.
This paper presents a robust nonlinear current-mode control approach for a pulse-width modulated DC-DC Cuk converter in a simple analog form. The control scheme is developed based on the reduced-state sliding-mode current control technique, in which a simplified equivalent control equation is derived using an averaged power converter model in continuous conduction mode. The proposed controller does not require an output capacitor current sensor and double proportional-integral compensators as in conventional sliding-mode current controllers; thus, the cost and complexity of the practical implementation is minimized without degrading the control performance. The simplified nonlinear controller rejects large disturbances, provides fast transient response, and maintains a constant switching frequency. The nonlinear control scheme is developed using an analog circuit with minimal added components, which is suitable for low-cost industrial applications. The control law derivation, control circuit design, controller gains selection, and stability analysis are provided. The proposed control methodology is verified via simulating the closed-loop nonlinear power converter model in MATLAB/SIMULINK under abrupt changes in load current and input voltage. The simulation results show that the proposed control scheme provides robust tracking performance, a low percentage overshoot, fast transient response, and a wide operating range. The maximum percentage overshoot and settling time of the closed-loop power converter response during line disturbance are 5.6% and 20 ms, respectively, whereas the percentage overshoot and settling time during load disturbance are 2.8% and 15 ms, respectively.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available