4.7 Article

Simultaneous detection of dihydroxybenzene isomers in the environment by a free-standing flexible ZnCo2O4 nanoplate arrays/carbon fiber cloth electrode

Journal

SCIENCE OF THE TOTAL ENVIRONMENT
Volume 855, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.scitotenv.2022.158878

Keywords

Simultaneous determination; Dihydroxybenzene isomers; Flexible electrode; Electrochemical sensor

Ask authors/readers for more resources

In this study, a free-standing flexible electrode was developed for the simultaneous detection of dihydroxybenzene isomers. The electrode exhibited fast electron transmission, abundant active sites, and excellent enzyme-like kinetic performance. It showed a wider linear response range, lower detection limits, and higher sensitivity. Moreover, the electrochemical sensor demonstrated excellent detection performance in complex water samples, providing a strategy for the detection of other toxic substances in the ecological environment.
The simultaneous determination of dihydroxybenzene isomers is highly valuable for early environmental monitoring, but it is still a challenge. In this work, a free-standing flexible electrode was prepared for the simultaneous detection of hydroquinone (HQ), catechol (CC), and resorcinol (RC). The bimetallic zinc/cobalt zeolitic imidazolate frameworks nanoplate arrays (Zn/Co-ZIF NPAs) grown in situ on the carbon fiber cloth (CFC) was fabricated by a facile static synthesis method, and the porous ternary ZnCo2O4 NPAs derived from Zn/Co-ZIF NPAs were formed by annealing in air. Due to the fast electron transmission, abundant active sites and excellent electrocatalytic properties with enzyme-like kinetic performance of the ZnCo2O4/CFC electrode, the as-proposed sensor showed a wilder linear response (2-500 mu M), a lower detection limits (0.03 mu M HQ, 0.06 mu M CC and 0.15 mu M RC) and a higher sensitivity (23.58 mu A mu M-1 cm-2 HQ, 17.72 mu A mu M-1 cm-2 CC, and 15.18 mu A mu M-1 cm-2 RC), respectively. More importantly, the proposed electrochemical sensor exhibited excellent detection performance in complex water samples, providing a strategy for the detection of other toxic substances in the ecological environment.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available