4.5 Article

Comparison of trace element concentrations in paired formalin-fixed paraffin-embedded and frozen human placentae

Journal

PLACENTA
Volume 131, Issue -, Pages 98-103

Publisher

W B SAUNDERS CO LTD
DOI: 10.1016/j.placenta.2022.12.003

Keywords

-

Ask authors/readers for more resources

There is growing interest in measuring metals concentrations in human placentas for various purposes, but the comparison between formalin-fixed paraffin embedded (FFPE) tissues and frozen tissues has been limited. In this study, paired samples of frozen and FFPE tissue from 22 human placentae were analyzed for metal concentrations, and the results showed no significant differences between the two types of tissue preparations.
Introduction: There is increasing interest in measuring metals concentrations in human placentas to better understand physiology, disease, and toxic and diagnostic exposures. For these purposes, formalin-fixed paraffin embedded (FFPE) tissues obtained at clinical pathology examination represent a valuable potential store of well-characterized tissues for analysis. However, the limited data that exist comparing metal concentrations in FFPE tissue to recently collected frozen tissues paints a confusing picture, and there is no published data directly comparing frozen and FFPE placental villus tissues. Methods: Paired samples of fresh frozen and FFPE tissue from 22 rapidly processed human singleton placentae were weighed and digested using standard clean laboratory procedures and subsequently analyzed for a suite of 13 metals using a PerkinElmer DRC II ICP-MS. The analytical results were compared using either a paired t-test or a sign test depending on data normality.Results: Concentrations of metals (aluminum (Al), arsenic (As), barium (Ba), cadmium (Cd), chromium (Cr), copper (Cu), iron (Fe), gadolinium (Gd), mercury (Hg), manganese (Mn), lead (Pb), strontium (Sr), and zinc (Zn)) measured in both types of tissue preparations (frozen and FFPE) displayed a consistent range with other studies and did not display significantly different values from each of the paired specimens for any of the 13 specific metals analyzed.Discussion: Within placentae, metals concentrations of measured trace, toxic and diagnostic elements (Al, As, Ba, Cd, Cr, Cu, Fe, Gd, Hg, Mn, Pb, Sr, and Zn) are consistent between FFPE and fresh placental villus tissue, without indications of systematic element loss or bias. FFPE from archived pathology specimens may offer an important and convenient alternative for measuring trace metals in human frozen placental tissues.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available