4.4 Article

Oscillatory mechanics in very preterm infants on continuous positive airway pressure support: Reference values

Journal

PEDIATRIC PULMONOLOGY
Volume 58, Issue 3, Pages 746-752

Publisher

WILEY
DOI: 10.1002/ppul.26247

Keywords

forced oscillation technique; infant lung function testing; respiratory mechanics

Ask authors/readers for more resources

The study aimed to establish reference values for respiratory system resistance (Rrs) and reactance (Xrs) measured by the forced oscillation technique (FOT) in nonintubated very preterm infants. The results showed that Xrs was significantly associated with gestational age, postnatal age, weight, and length at continuous positive airway pressure (CPAP) of 5 cmH(2)O, while Rrs was not significantly associated.
Objective: To create reference values for respiratory system resistance (Rrs) and reactance (Xrs) measured by the forced oscillation technique (FOT) in nonintubated very preterm infants. Design: Retrospective analysis of data collected as part of prospective observational studies in two centers. Setting: Tertiary neonatal intensive care units. Patients: Non-intubated infants below 32 weeks' gestation age who did not develop bronchopulmonary dysplasia. Interventions: We applied FOT using a mechanical ventilator (Fabian HFOi; Vyaire) that superimposed small-amplitude oscillations (10 Hz) on a continuous positive airway pressure of 3 and 5 cmH(2)O. Measurements were performed during regular tidal breathing using a face mask. Main outcome measures: We analyzed 198 measurements performed between 7 postnatal days and 40 weeks postmenstrual age (PMA) in 85 infants, with a median (Q1, Q3) gestational age of 30.43 (29.14, 31.18) weeks. Logarithmic transformations were applied to Rrs and Xrs, and the relationship between transformed impedance values and demographic factors was examined by backwards stepwise linear regression. Results: In univariable analysis, transformed Xrs was significantly associated with PMA, postnatal age, weight, and length, while Rrs was not. The best multivariable regression model estimating transformed Xrs (cmH(2)O*s/L) at continuous positive airway pressure (CPAP) = 5 cmH(2)O was: In(50 - Xrs) = 4.892 - 0.021 x PMA (in weeks) - 0.017 x weight z-score standard error of the estimate ([SEE] = 0.053, R-2 adjusted = 0.35). The mean (SD) Rrs at CPAP = 5 cmH(2)O was 33.63 (5.28) cmH(2)O*s/L. Conclusion: We have established reference values for Rrs and Xrs at 10 Hz in nonintubated preterm neonates on continuous positive airway pressure support.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available