4.1 Article

Bilateral septal pacing in combination with coronary venous pacing for cardiac resynchronization therapy

Journal

PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY
Volume 46, Issue 3, Pages 226-234

Publisher

WILEY
DOI: 10.1111/pace.14628

Keywords

bilateral septal pacing; cardiac resynchronization therapy; interventricular septum; QRS duration

Ask authors/readers for more resources

This study evaluated the effectiveness of QRS narrowing by bilateral septal pacing (BSP) in combination with coronary venous pacing (CVP) for cardiac resynchronization therapy (CRT). The results showed that BSP-CRT had a significant advantage in QRS narrowing and could be considered as an alternative to CRT for patients with QRS duration more than 130 ms. At 3-month follow-up, left ventricular ejection fraction improved.
BackgroundConventional right ventricular pacing combined with coronary venous pacing (CVP) is a mainstay for cardiac resynchronization therapy (CRT). However, QRS duration of conventional CRT may be frequently more than 130 ms. This study aimed to evaluate the effectiveness of QRS narrowing by bilateral septal pacing (BSP) in combination with CVP for CRT (BSP-CRT). MethodsFourteen patients with QRS > 130 ms of conventional CRT after failure of physiological conduction system pacing were enrolled. Electrophysiologic characteristics were compared among different modes of CRT during procedure. BSP which was defined as capture of both sides of interventricular septum manifested as shortened R wave peak time without a right bundle branch block QRS pattern. ResultsBSP-CRT were successfully achieved in 85.7% (12/14) patients. QRS duration at baseline was 185 +/- 13 ms and significantly narrowed to 156 +/- 9 ms during conventional CRT (n = 14, P < .001), to 143 +/- 7 ms during left ventricular septal pacing (LVSP) in combination with CVP for CRT (LVSP-CRT) (n = 9, P < .001), and further to 122 +/- 10 ms during BSP-CRT (n = 12, P < .001). Notably, among 7 patients in whom both LVSP and BSP were achieved, BSP-CRT outperformed LVSP-CRT at QRS narrowing by 16% (P < .001). At 3-month follow-up, left ventricular ejection fraction improved from 29 +/- 6% to 41 +/- 8% (P < .001). ConclusionsBSP-CRT resulted in superior acute electrical synchronization to conventional CRT and might be considered as an alternative to conventional CRT with QRS more than 130 ms.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available