4.6 Article

A Comparative Study between Screen-Printed and Solid-Contact Electrodes for the Stability-Indicating Determination of Bromazepam

Related references

Note: Only part of the references are listed.
Article Chemistry, Analytical

Potentiometric Sensors for the Selective Determination of Benzodiazepine Drug Residues in Real Wastewater Effluents

Sherif A. Abdel-Gawad et al.

Summary: The application of ion-selective electrodes in the detection and determination of environmental pollutants is crucial. By using membrane electrodes and adjusting assay settings, bromazepam can be accurately measured in real wastewater samples without tedious pretreatment procedures.

CHEMOSENSORS (2022)

Article Biochemical Research Methods

Qualitative and semi-quantitative screening of selected psychoactive drugs in blood: Usefulness of liquid chromatography-triple quadrupole and quadrupole time-of-flight mass spectrometry in routine toxicological analyses

Maarten Degreef et al.

Summary: This study compares two easy-to-use screening methods for routine toxicological analysis. After analyzing 105 medico-legal case samples, it was found that both methods are effective for screening most compounds in toxicological analysis. The semi-quantitative analysis using the tMRM method with a small number of labeled internal standards yielded excellent results, while the semi-quantitative analysis using the QTOF method was more time-consuming.

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES (2022)

Article Chemistry, Analytical

Novel Micro Flow Injection Analysis System for the Potentiometric Determination of Tetraborate Ions in Environmental Samples

Cihan Topcu et al.

Summary: A novel micro flow injection analysis system was developed for the potentiometric determination of tetraborate ions in environmental samples. The tetraborate selective sensor exhibited superior performance with a supra-Nernstian slope and low detection limit. The sensor also demonstrated good operational stability and repeatability in the flow injection analysis system, making it suitable for direct potentiometric determination of tetraborate ions in environmental samples.

ANALYTICAL LETTERS (2021)

Article Multidisciplinary Sciences

Development and validation of a stability indicating RP-HPLC-DAD method for the determination of bromazepam

Hany W. Darwish et al.

Summary: A reliable RP-HPLC assay was developed for the quantitation of bromazepam and its degradant, with results indicating its suitability for impurity quantitation in pure samples as well as pharmaceutical dosage forms. The method adhered to ICH guidelines and showed no significant differences in accuracy and precision compared to a reference HPLC method.

PLOS ONE (2021)

Article Spectroscopy

Stability indicating spectrophotometric methods for quantitative determination of bromazepam and its degradation product

Hany W. Darwish et al.

SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY (2020)

Review Chemistry, Analytical

Electrochemical Sensors and Biosensors Based on Nanomaterials and Nanostructures

Chengzhou Zhu et al.

ANALYTICAL CHEMISTRY (2015)

Article Biochemical Research Methods

A rapid and accurate UPLC/MS/MS method for the determination of benzodiazepines in human urine

Dong Sheng Ming et al.

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES (2011)

Article Chemistry, Analytical

A novel procedure for rapid surface functionalisation and mediator loading of screen-printed carbon electrodes

Nikolay A. Pchelintsev et al.

ANALYTICA CHIMICA ACTA (2008)

Article Biochemical Research Methods

Development and validation of an HPLC method for the simultaneous monitoring of bromazepam and omeprazole

Gregory Podilsky et al.

JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES (2008)

Article Biochemical Research Methods

Development and validation of an HPLC method for the determination of six 1,4-benzodiazepines in pharmaceuticals and human biological fluids

Mohammad Nasir Uddin et al.

JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES (2008)

Article Chemistry, Analytical

Validation of SPE-HPLC determination of 1,4-benzodiazepines and metabolites in blood plasma, urine, and saliva

Mohammad Nasir Uddin et al.

JOURNAL OF SEPARATION SCIENCE (2008)

Article Chemistry, Analytical

Separation and HPLC analysis of 15 benzodiazepines in human plasma

Laura Mercolini et al.

JOURNAL OF SEPARATION SCIENCE (2008)

Article Biochemical Research Methods

Separation of 1,4-benzodiazepines by micellar elektrokinetic capillary chromatography

Gabriel Hancu et al.

JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS (2007)

Review Chemistry, Analytical

Electrochemical sensors

Eric Bakker et al.

ANALYTICAL CHEMISTRY (2006)

Article Spectroscopy

Spectrophotometric and fluorimetric determination of diazepam, bromazepam and clonazepam in pharmaceutical and urine samples

AA Salem et al.

SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY (2004)

Article Chemistry, Analytical

Potentiometric determination of some 1,4-benzodiazepines in pharmaceutical preparations and biological samples

AEA Salem et al.

JOURNAL OF ELECTROANALYTICAL CHEMISTRY (2002)

Article Medicine, Legal

Quantitation using GC-TOF-MS: example of bromazepam

B Aebi et al.

FORENSIC SCIENCE INTERNATIONAL (2002)