4.6 Article

Simultaneous Determination of Orelabrutinib, Zanubrutinib, Ibrutinib and Its Active Metabolite in Human Plasma Using LC-MS/MS

Journal

MOLECULES
Volume 28, Issue 3, Pages -

Publisher

MDPI
DOI: 10.3390/molecules28031205

Keywords

Bruton's tyrosine kinase inhibitor; human plasma; LC-MS; MS

Ask authors/readers for more resources

In this study, an LC-MS/MS method was developed and validated for the determination of orelabrutinib, zanubrutinib, ibrutinib, and its active metabolite dihydrodiol ibrutinib in human plasma. The method demonstrated good selectivity, precision, accuracy, and other validation parameters. It was successfully applied to quantify the plasma levels of these drugs in clinical patients.
Ibrutinib, orelabrutinib, and zanubrutinib are all Bruton's tyrosine kinase inhibitors, which have greatly improved the treatment of B-cell malignancies. In this study, an LC-MS/MS method was developed and validated for the determination of orelabrutinib, zanubrutinib, ibrutinib, and its active metabolite dihydrodiol ibrutinib in human plasma. The Ibrutinib-d5 was used as the internal standard. Pretreatment was performed using a simple protein precipitation step using acetonitrile. The ACQUITY UPLC HSS T3 column (2.1x50 mm, 1.8 mu m) was used to separate the analytes, and the run time was 6.5 min. The mobile phase consisted of acetonitrile and 10 mM of ammonium formate, which contained 0.1% formic acid. The multiple reactions' monitoring transitions were selected at m/z 428.1 -> 411.2, 472.2 -> 455.2, 441.1 -> 304.2, 475.2 -> 304.2 and 446.2 -> 309.2 respectively for orelabrutinib, zanubrutinib, ibrutinib, dihydrodiol ibrutinib and ibrutinib-d5 using positive ion electrospray ionization. The standard curves were linear, from 0.400 to 200 ng/mL for ibrutinib and dihydrodiol ibrutinib, 1.00-500 ng/mL for orelabrutinib, and 2.00-1000 ng/mL for zanubrutinib. Selectivity, the lower limit of quantitation, precision, accuracy, matrix effect, recovery, stability, and dilution integrity all met the acceptance criteria of FDA guidance. This method was used to quantify the plasma levels of orelabrutinib, zanubrutinib, ibrutinib, and dihydrodiol ibrutinib in clinical patients.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available