4.6 Article

A new method for rapid determination of indole-3-carbinol and its condensation products in nutraceuticals using core-shell column chromatography method

Journal

JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
Volume 120, Issue -, Pages 383-390

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jpba.2015.12.039

Keywords

Indole-3-carbinol; Nutraceuticals; Condensation products; Liquid chromatography; Core-shell columns; Quality control

Funding

  1. [SW 260 184]

Ask authors/readers for more resources

Indole-3-carbinol is a natural glucosinolate known for prevention of human breast, prostate and other types of cancer and it started to be used in commercial preparations, as food supplements. However no analytical method has been proposed for quality control of nutraceuticals with this substance yet. In this paper a new high-performance liquid chromatography (HPLC) method using core-shell column for separation of indole-3-carbinol and its condensation/degradation products was developed and used for the quantitative determination of indole-3-carbinol in nutraceuticals. Separation of indole-3-carbinol, its condensation/degradation products and internal standard ethylparaben was performed on the core-shell column Kinetex 5 mu XB-C18 100A (100 x 4.6 mm), particle size 5.0 mu m, with mobile phase acetonitrile/water according to the gradient program at a flow rate of 1.25 mL min(-1) and at temperature 50 degrees C. The detection wavelength was set at 270 nm. Under the optimal chromatographic conditions good linearity of determination was achieved. Available commercial samples of nutraceuticals were extracted with 100% methanol using ultrasound bath. A 5-mu L sample volume of the supernatant was directly injected into the HPLC system. The developed method provided rapid and accurate tool for quality control of nutraceuticals based on cruciferous vegetable extracts with indole-3-carbinol content. The presented study showed that the declared content of indole-3-carbinol significantly varied in the different nutraceuticals available on the market. Two analyzed preparations showed the presence of condensation/degradation products of indole-3-carbinol which were not officially declared by the manufacturer. Moreover, further two analyzed nutraceutical preparations showed absolutely no content of declared amount of indole-3-carbinol. (C) 2015 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available