4.7 Article

Error factors in precise thermal conductivity measurement using 3ω method for wire samples

Journal

JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY
Volume 148, Issue 6, Pages 2285-2296

Publisher

SPRINGER
DOI: 10.1007/s10973-022-11892-6

Keywords

3 omega method; Thermal conductivity; Wire sample; Error analysis

Ask authors/readers for more resources

Accurate thermal conductivity measurement is crucial for designing microscale thermoelectric and heat transfer devices. The 3 omega method is one of the best methods for measuring conductive wires, as it directly measures thermal conductivity without the need for measuring density or specific heat. However, previous studies did not adequately consider the effects of ambient pressure and conductive adhesive, which could affect the accuracy of measurement. This study investigated the influence of ambient pressure and the length of conductive adhesive on the 3 omega method, providing guidelines for more accurate determination of thermal conductivity.
In designing thermoelectric and heat transfer devices on the micrometer scale, the accurate thermal conductivity measurement is very important, and a variety of measurement methods have been developed so far. Among them, the 3 omega method is one of the best for conductive wires because it can directly measure thermal conductivity without measuring density or specific heat, and also in the same direction as electrical or thermoelectric property. However, previous studies have not sufficiently considered the effects of ambient pressure and the conductive adhesive used to attach the sample to the electrode, which may hinder accurate measurement. In this study, using a thin gold wire as a test sample, the influence of ambient pressure and the length of conductive adhesive along the sample has been investigated quantitatively as major factors of systematic errors in the 3 omega method. When the pressure was increased in the transition flow region, the measured apparent thermal conductivity increased. An analytical model for the low-pressure gas heat conduction is proposed to quantitatively explain the pressure dependence. The measured value also increased when the length of the conductive adhesive exceeded 20% of the sample length. This work has revealed that the ambient should be evacuated to the molecular flow region and the length of conductive adhesive be less than 20% of the sample length. The guidelines proposed here will help researchers in various fields to more accurately determine the thermal conductivity of micrometer-scale wires.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available