4.4 Article

Electron-counting MicroED data with the K2 and K3 direct electron detectors

Journal

JOURNAL OF STRUCTURAL BIOLOGY
Volume 214, Issue 4, Pages -

Publisher

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.jsb.2022.107886

Keywords

MicroED; cryo-EM; Direct electron detector; Protein crystals

Funding

  1. National Institutes of Health [P41GM136508, R01GM124152]
  2. Department of Defense [HDTRA1-21-1-0004]
  3. Howard Hughes Medical Institute

Ask authors/readers for more resources

Microcrystal electron diffraction (MicroED) is a technique that uses electron cryo-microscopy (cryo-EM) to collect diffraction data from small crystals. In this study, the researchers used direct electron detectors, K2 and K3, to successfully determine macromolecular structures between 1.2 ? and 2.8 ? resolution. They also found that the cameras were not damaged even without using a beam stop. This study highlights the potential of using readily available cryo-EM facilities for MicroED experiments.
Microcrystal electron diffraction (MicroED) uses electron cryo-microscopy (cryo-EM) to collect diffraction data from small crystals during continuous rotation of the sample. As a result of advances in hardware as well as methods development, the data quality has continuously improved over the past decade, to the point where even macromolecular structures can be determined ab initio. Detectors suitable for electron diffraction should ideally have fast readout to record data in movie mode, and high sensitivity at low exposure rates to accurately report the intensities. Direct electron detectors are commonly used in cryo-EM imaging for their sensitivity and speed, but despite their availability are generally not used in diffraction. Primary concerns with diffraction experiments are the dynamic range and coincidence loss, which will corrupt the measurement if the flux exceeds the count rate of the detector. Here, we describe instrument setup and low-exposure MicroED data collection in electroncounting mode using K2 and K3 direct electron detectors and show that the integrated intensities can be effectively used to solve structures of two macromolecules between 1.2 ?, and 2.8 ?, resolution. Even though a beam stop was not used with the K3 studies we did not observe damage to the camera. As these cameras are already available in many cryo-EM facilities, this provides opportunities for users who do not have access to dedicated facilities for MicroED.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available