4.7 Article

A performance comparison of two (electro) chemiluminescence immunoassays for detection and quantitation of serum anti-spike antibodies according to SARS-CoV-2 vaccination and infections status

Journal

JOURNAL OF MEDICAL VIROLOGY
Volume 95, Issue 1, Pages -

Publisher

WILEY
DOI: 10.1002/jmv.28397

Keywords

antibodies; DiaSorin immunoassay; neutralizing antibodies; receptor binding domain antibodies; Roche immunoassay; SARS-CoV-2; S-trimeric antibodies

Categories

Ask authors/readers for more resources

The information provided by SARS-CoV-2 spike (S)-targeting immunoassays is important in clinical-decision making. The performance of two immunoassays, Elecsys (R) Anti-SARS-CoV-2 S assay and LIAISON (R) SARS-CoV-2 TrimericS IgG assay, was compared using sera from vaccinated and unvaccinated individuals. The results showed that the Roche assay had a higher number of positive results and overall sensitivity, and the concordance between the two assays varied depending on the vaccination and infection status.
The information provided by SARS-CoV-2 spike (S)-targeting immunoassays can be instrumental in clinical-decision making. We compared the performance of the Elecsys (R) Anti-SARS-CoV-2 S assay (Roche Diagnostics) and the LIAISON (R) SARS-CoV-2 TrimericS IgG assay (DiaSorin) using a total of 1176 sera from 797 individuals, of which 286 were from vaccinated-SARS-CoV-2/experienced (Vac-Ex), 581 from vaccinated/naive (Vac-N), 147 from unvaccinated/experienced (Unvac-Ex), and 162 from unvaccinated/naive (Unvac-N) individuals. The Roche assay returned a higher number of positive results (907 vs. 790; p = 0.45; overall sensitivity: 89.3% vs. 77.6%). The concordance between results provided by the two immunoassays was higher for sera from Vac-N (kappa: 0.58; interquartile ranges [IQR]: 0.50-0.65) than for sera from Vac-Ex (kappa: 0.19; IQR: -0.14 to 0.52) or Unvac-Ex (kappa: 0.18; IQR: 0.06-0.30). Discordant results occurred more frequently among sera from Unvac-Ex (34.7%) followed by Vac-N (14.6%) and Vac-Ex (2.7%). Antibody levels quantified by both immunoassays were not significantly different when <250 (p = 0.87) or <1000BAU/ml (p = 0.13); in contrast, for sera >= 1000BAU/ml, the Roche assay returned significantly higher values than the DiaSorin assay (p < 0.008). Neutralizing antibody titers (NtAb) were measured in 127 sera from Vac-Ex or Vac-N using a S-pseudotyped virus neutralization assay of Wuhan-Hu-1, Omicron BA.1, and Omicron BA.2. The correlation between antibody levels and NtAb titers was higher for sera from Vac-N than those from Vac-Ex, irrespective of the (sub)variant considered. In conclusion, neither qualitative nor quantitative results returned by both immunoassays are interchangeable. The performance of both assays was found to be greatly influenced by the vaccination and SARS-CoV-2 infection status of individuals.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available