4.7 Article

Treatment with integrase inhibitors alters SARS-CoV-2 neutralization levels measured with HIV-based pseudotypes in people living with HIV

Journal

JOURNAL OF MEDICAL VIROLOGY
Volume 95, Issue 2, Pages -

Publisher

WILEY
DOI: 10.1002/jmv.28543

Keywords

HIV-1; neutralization; pseudoviruses; SARS-CoV-2

Categories

Ask authors/readers for more resources

This study compares two methods using HIV and VSV-based pseudoviruses to detect neutralizing antibodies (NAbs) against SARS-CoV-2 in people living with HIV (PLWH). The HIV-pseudoparticles method shows higher neutralization titers, but also detects NAbs in COVID-19-naive PLWH. Treatment with integrase inhibitors can lead to inaccurate results when using the HIV-based pseudoviruses method, but this interference can be eliminated through IgG purification.
The presence of neutralizing antibodies (NAbs) is a major correlate of protection for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. Thus, different in vitro pseudoviruses-based assays have been described to detect NAbs against SARS-CoV-2. However, the determination of NAbs against SARS-CoV-2 in people living with HIV (PLWH) through HIV-based pseudoparticles could be influenced by cross-neutralization activity or treatment, impeding accurate titration of NAbs. Two assays were compared using replication-defective HIV or VSV-based particles pseudotyped with SARS-CoV-2 spike to measure NAbs in COVID-19-recovered and COVID-19-naive PLWH. The assay based on HIV-pseudoparticles displayed neutralization activity in all COVID-19-recovered PLWH with a median neutralizing titer 50 (NT50) of 1417.0 (interquartile range [IQR]: 450.3-3284.0), but also in 67% of COVID-19-naive PLWH (NT50: 631.5, IQR: 16.0-1535.0). Regarding VSV-pseudoparticles system, no neutralization was observed in COVID-19-naive PLWH as expected, whereas in comparison with HIV-pseudoparticles assay lower neutralization titers were measured in 75% COVID-19-recovered PLWH (NT50: 100.5; IQR: 20.5-1353.0). Treatment with integrase inhibitors was associated with inaccurate increase in neutralization titers when HIV-based pseudoparticles were used. IgG purification and consequent elimination of drugs from samples avoided the interference with retroviral cycle and corrected the lack of specificity observed in HIV-pseudotyped assay. This study shows methodological alternatives based on pseudoviruses systems to determine specific SARS-CoV-2 neutralization titers in PLWH.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available