4.7 Article

Diffusion-Weighted Imaging of the Abdomen: Correction for Gradient Nonlinearity Bias in Apparent Diffusion Coefficient

Related references

Note: Only part of the references are listed.
Article Radiology, Nuclear Medicine & Medical Imaging

Gradient nonlinearity correction in liver DWI using motion-compensated diffusion encoding waveforms

Sean McTavish et al.

Summary: The experimental results demonstrate that the gradient nonlinearity correction method effectively reduces ADC bias in various diffusion encoding waveforms and may further increase ADC overestimation in in vivo experiments due to motion and residual vessel signal.

MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Technical Note: Temperature and concentration dependence of water diffusion in polyvinylpyrrolidone solutions

Ghoncheh Amouzandeh et al.

Summary: The objective of this work is to calibrate the temperature and concentration calibration of water diffusivity in PVP solutions for ADC measurements. The study provides ground-truth ADC values for K40 PVP solutions and offers calibration procedures and parameters for quality control and standardization of measured ADC values of PVP at different concentrations and temperatures.

MEDICAL PHYSICS (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Long-Term Stability of Gradient Characteristics Warrants Model-Based Correction of Diffusion Weighting Bias

Yuxi Pang et al.

Summary: The study examines the long-term stability of gradient characteristics for model-based correction of diffusion weighting bias in multisite imaging trials. The results indicate that the model-based correction can effectively reduce the bias, while residual errors due to eddy currents and shim gradients should be corrected independently.

TOMOGRAPHY (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Technical Basics of Diffusion-Weighted Imaging

Masaaki Hori et al.

MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Mapping gradient nonlinearity and miscalibration using diffusion-weighted MR images of a uniform isotropic phantom

Alan Seth Barnett et al.

Summary: This method uses diffusion measurements to map the spatial dependence of the magnetic field produced by the gradient coils of an MRI scanner with sufficient accuracy to correct errors in quantitative diffusion MRI. The results demonstrate substantial reduction in spatial inhomogeneity of computed mean diffusivities and values of fractional anisotropy, as well as elimination of artifactual directional bias in the tensor field due to gradient nonlinearity.

MAGNETIC RESONANCE IN MEDICINE (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Empirical validation of gradient field models for an accurate ADC measured on clinical 3T MR systems in body oncologic applications

Yuxi Pang et al.

Summary: The study empirically verified the gradient nonlinearity characteristics provided by different vendors on 3T MR systems and demonstrated the effectiveness of GNL bias correction for human brain apparent diffusion coefficient (ADC). The results showed that accurate WM ADC was recovered using system-specific tensor-based GNL correction, regardless of spatial locations and clinical MR platforms.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Consensus-based technical recommendations for clinical translation of renal diffusion-weighted MRI

Alexandra Ljimani et al.

MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE (2020)

Review Radiology, Nuclear Medicine & Medical Imaging

Diffusion MRI of cancer: From low to high b-values

Lei Tang et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2019)

Review Radiology, Nuclear Medicine & Medical Imaging

Quantitative imaging biomarkers alliance (QIBA) recommendations for improved precision of DWI and DCE-MRI derived biomarkers in multicenter oncology trials

Amita Shukla-Dave et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2019)

Article Biochemical Research Methods

The generalized Stejskal-Tanner equation for non-uniform magnetic field gradients

Karol Borkowski et al.

JOURNAL OF MAGNETIC RESONANCE (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Improving apparent diffusion coefficient accuracy on a compact 3T MRI scanner using gradient nonlinearity correction

Ashley T. Tao et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

An Acetone-Based Phantom for Quantitative Diffusion MRI

Xiaoke Wang et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Technical Note: A safe, cheap, and easy-to-use isotropic diffusion MRI phantom for clinical and multicenter studies

Pim Pullens et al.

MEDICAL PHYSICS (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Demonstration of nonlinearity bias in the measurement of the apparent diffusion coefficient in multicenter trials

Dariya I. Malyarenko et al.

MAGNETIC RESONANCE IN MEDICINE (2016)

Review Radiology, Nuclear Medicine & Medical Imaging

Diffusion-weighted imaging outside the brain: Consensus statement from an ISMRM-sponsored workshop

Bachir Taouli et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Technical advancements and protocol optimization of diffusion-weighted imaging (DWI) in liver

Ping Ni et al.

ABDOMINAL RADIOLOGY (2016)

Review Radiology, Nuclear Medicine & Medical Imaging

Diffusion-weighted magnetic resonance imaging in cancer: Reported apparent diffusion coefficients, in-vitro and in-vivo reproducibility

Maysam M. Jafar et al.

WORLD JOURNAL OF RADIOLOGY (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Diffusion-weighted MR Imaging of the Pancreas: Current Status and Recommendations

Matthias Barral et al.

RADIOLOGY (2015)

Article Radiology, Nuclear Medicine & Medical Imaging

Practical Estimate of Gradient Nonlinearity for Implementation of Apparent Diffusion Coefficient Bias Correction

Dariya I. Malyarenko et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2014)

Article Radiology, Nuclear Medicine & Medical Imaging

Analysis and Correction of Gradient Nonlinearity Bias in Apparent Diffusion Coefficient Measurements

Dariya I. Malyarenko et al.

MAGNETIC RESONANCE IN MEDICINE (2014)

Article Radiology, Nuclear Medicine & Medical Imaging

Improved correction for gradient nonlinearity effects in diffusion-weighted imaging

Ek T. Tan et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2013)

Article Radiology, Nuclear Medicine & Medical Imaging

Geometric distortion in clinical MRI systems - Part I: evaluation using a 3D phantom

D Wang et al.

MAGNETIC RESONANCE IMAGING (2004)

Article Radiology, Nuclear Medicine & Medical Imaging

Analysis and generalized correction of the effect of spatial gradient field distortions in diffusion-weighted imaging

R Bammer et al.

MAGNETIC RESONANCE IN MEDICINE (2003)