4.6 Article

Label-free high-resolution white light quantitative phase nanoscopy system

Journal

JOURNAL OF BIOPHOTONICS
Volume 16, Issue 4, Pages -

Publisher

WILEY-V C H VERLAG GMBH
DOI: 10.1002/jbio.202200298

Keywords

deconvolution; high-resolution; imaging; phase nanoscopy; phase-shifting; white light

Ask authors/readers for more resources

We introduce a high-resolution white light quantitative phase nanoscopy (WLQPN) system for visualizing nanoparticles and subcellular features in biological specimens. The system utilizes the five-phase shifting technique and deconvolution to achieve super-resolution phase imaging. Compared to the Fourier analysis method, the phase shifting technique provides full detector resolution. The technique was tested on various samples and showed significant improvement in resolution.
We present a high-resolution white light quantitative phase nanoscopy (WLQPN) system that can be utilized to visualize nanoparticles and subcellular features of the biological specimens. The five-phase shifting technique, along with deconvolu-tion, is adopted to obtain super-resolution in phase imaging. The phase shifting technique can provide full detector reso-lution, making it beneficial as compared to the well-known Fourier analysis method. The Fourier transform method requires minimum angle of sin-1 eth 3fx lambda THORN , where fx is maximum achievable spatial frequency. It limits the highest achievable resolution to much below the actual diffraction limit of the system. Thus, to obtain a high-resolution phase map of the biological speci -men, a two-step process is adopted. First, the phase map is recovered using the five-phase shifting algorithm, with full detector spatial resolution. Second, the complex field is obtained from the recovered phase map and further processed using the Richardson Lucy total variation deconvolution algorithm to obtain super-resolution phase images. The present technique was tested on 1951 USAF resolution chart, 200 nm polystyrene beads and Escherichia coli bacteria using a 50x, 0.55NA objective lens. The 200 nm polystyrene beads are visually resolvable and subcellular features of the E. coli bacteria are also observed, sug-gesting a significant improvement in the resolution.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available