4.7 Article

Ratiometric electrochemical sensor based on polythionine/multiwalled carbon nanotube composite for butylated hydroxyanisole determination

Related references

Note: Only part of the references are listed.
Article Chemistry, Multidisciplinary

Study of Electrochemical Mechanisms Using Computational Simulations: Application to Phenol Butylated Hydroxyanisole

Valeria Tapia Mattar et al.

Summary: Understanding the physicochemical properties of organic compounds with potential biological uses is crucial for current research. This proposal suggests using computational chemistry and experimental data to study the oxidation mechanism of the commonly used commercial antioxidant BHA. By analyzing both thermodynamic and kinetic information, the most likely oxidation path of BHA can be determined. Overall, this systematic approach allows students to study the physicochemical behavior of organic molecules in a research-like environment.

JOURNAL OF CHEMICAL EDUCATION (2022)

Article Chemistry, Analytical

Carbon dots-thionine modified aptamer-based biosensor for highly sensitive cocaine detection

Sajad Azizi et al.

Summary: This report introduces an aptasensor with higher sensitivity and selectivity, which monitors cocaine by immobilizing capture DNA on the surface of an ITO electrode modified with gold nanoparticles. The experimental results demonstrate the feasibility and practicality of this aptasensor.

JOURNAL OF ELECTROANALYTICAL CHEMISTRY (2022)

Article Chemistry, Analytical

Determination of the Synthetic Antioxidants Butylated Hydroxyanisole (BHA) and Butylated Hydroxytoluene (BHT) by Matrix Acidity-Induced Switchable Hydrophilicity Solvent-Based Homogeneous Liquid-Liquid Microextraction (MAI-SHS-HLLME) and High-Performance Liquid Chromatography with Ultraviolet Detection (HPLC-UV)

Elif Yildiz et al.

Summary: A rapid and easy sample pretreatment procedure was developed for the isolation of synthetic antioxidants from vinegar samples. The method, based on matrix acidity-induced switchable hydrophilicity solvent-based homogeneous liquid-liquid microextraction, showed good precision and recovery rates for spiked apple, grape, and white vinegar samples. The analytes were analyzed using high performance liquid chromatography with ultraviolet detection under optimized conditions, with limits of detection ranging from 3.2 to 5.5 μg L-1.

ANALYTICAL LETTERS (2022)

Article Chemistry, Applied

Trace analysis of multiple synthetic phenolic antioxidants in foods by liquid chromatography-tandem mass spectrometry with complementary use of electrospray ionization and atmospheric pressure chemical ionization

Bibai Du et al.

Summary: This study introduced a universal LC-MS/MS method for trace analysis of multiple synthetic phenolic antioxidants (SPAs) in foods, utilizing both ESI and APCI for sensitive analysis. Method performance assessment demonstrated satisfactory accuracy and precision in analyzing SPAs in various food matrices.

FOOD CHEMISTRY (2022)

Article Chemistry, Physical

A sensitive electrochemical sensor manufactured from multi-wall carbon nanotubes-polyethylenimine nanocomposite for malachite green detection

Yuezhong Luo et al.

Summary: In this study, a modified electrode with multi-walled carbon nanotubes-polyethylenimine composites was used to detect malachite green in aquaculture, showing excellent catalytic performance and a relatively low detection limit. The sensor demonstrated good accuracy, reproducibility, anti-interference ability, and rapid response in detecting malachite green in different samples.

JOURNAL OF ALLOYS AND COMPOUNDS (2022)

Article Chemistry, Analytical

Poly(Thionine)-Modified Screen-Printed Electrodes for CA 19-9 Detection and Its Properties in Raman Spectroscopy

Yuselis Castano-Guerrero et al.

Summary: Polythionine (PTH) is an electroactive compound known for its excellent electron transfer capacity. It has been widely used in various fields, including electrochemical biosensors. This study explores the ability of PTH as an electrochemical probe to detect CA 19-9 on different substrates and provides analytical features and potential complementary information applications.

CHEMOSENSORS (2022)

Article Electrochemistry

Facile fabrication of electrochemically reduced graphene oxide/polythionine-methylene blue and its use as a platform for detection of nicotinamide adenine dinucleotide in the artificial urine sample

Minling Ding et al.

Summary: In this study, a facile, rapid, selective, and stable electrochemical sensing platform for nicotinamide adenine dinucleotide (NADH) was developed. The platform utilized polythionine-methylene blue and electrochemically reduced graphene oxide modified glassy carbon electrode. The sensor exhibited a wide linear range, low detection limit, and negligible interference from ascorbic acid and uric acid. The sensor also showed promising biomedical applications in the determination of NADH in artificial urine samples.

ELECTROCHIMICA ACTA (2022)

Article Chemistry, Physical

Ultra-fast synthesis of iron decorated multiwalled carbon nanotube composite materials: A sensitive electrochemical sensor for determining dopamine

Haocheng Yang et al.

Summary: A highly efficient catalyst based on iron carbides was synthesized for real-time monitoring of dopamine levels, showing great selectivity and sensitivity down to 15 nM. The developed Fe/Fe3C@CNT electrode was successfully applied for dopamine detection in real samples, promising significant applications in electrochemical detection and biosensing.

JOURNAL OF ALLOYS AND COMPOUNDS (2022)

Article Chemistry, Applied

Electrochemical sensor for determination of butylated hydroxyanisole (BHA) in food products using poly O-cresolphthalein complexone coated multiwalled carbon nanotubes electrode

J. Jayadevi Manoranjitham et al.

Summary: In this study, an electrochemical sensor for the determination of BHA was developed by electropolymerization of OC over MWCNTs. The POC/MWCNTs electrode showed BHA oxidation occurring at 0.27 V, with a linear detection range from 0.33 mu M to 110 mu M and a detection limit of 0.11 mu M. Amperometric determination of BHA using chronoamperometric techniques confirmed the linear relationship. The real-time analysis of sensors was validated by analyzing packed potato chips samples.

FOOD CHEMISTRY (2021)

Article Chemistry, Analytical

Dual-ratiometric electrochemical sensor for propyl gallate detection

Chang Yin et al.

Summary: A dual-ratiometric electrochemical sensor was developed for propyl gallate (PG) detection using anthraquinone/multi-walled carbon nanotube/chitosan modified glassy carbon electrode (AQ/MWCNT/CS/GCE), which demonstrated enhanced sensitivity for PG detection. The sensor showed linear increase in two ratiometric signals, IPG/IAQ and IPG/IMWCNT, with increasing PG concentration, and achieved detection limits of 0.67 µM and 0.76 µM, respectively. The sensor was successfully applied for PG detection in edible oil samples.

JOURNAL OF ELECTROANALYTICAL CHEMISTRY (2021)

Article Chemistry, Analytical

Ratiometric electrochemical sensor for bisphenol A detection using a glassy carbon electrode modified with a poly(toluidine blue)/gold nanoparticle composite

Zhiyuan Sun et al.

Summary: A ratiometric electrochemical sensor for bisphenol A detection has been developed with high sensitivity, stability, and selectivity. The sensor successfully verified the application of BPA in water samples.

ANALYTICAL METHODS (2021)

Article Multidisciplinary Sciences

Butylated hydroxytoluene and Butylated hydroxyanisole induced cyto-genotoxicity in root cells of Allium cepa L.

Himadri Pandey et al.

Summary: The study found that different concentrations of preservatives have significant effects on the somatic cells of Allium cepa, leading to growth retardation, changes in cell texture, and alterations in genetic material. The highest concentration of preservatives exhibited higher genotoxicity.

HELIYON (2021)

Article Chemistry, Analytical

Electropolymerization of poly(methylene blue) on flower-like nickel-based MOFs used for ratiometric electrochemical sensing of total polyphenolic content in chrysanthemum tea

Chang Yin et al.

Summary: A ratiometric electrochemical sensor for detecting caffeic acid was constructed using poly(methylene blue) and flower-like nickel-based metal organic frameworks. The sensor exhibited a linear response to caffeic acid and was successfully used to evaluate the total polyphenolic content in chrysanthemum tea.

ANALYTICAL METHODS (2021)

Article Chemistry, Analytical

Electroanalytical determination of Bisphenol A: Investigation of electrode surface fouling using various carbon materials

Abdelghani Ghanam et al.

JOURNAL OF ELECTROANALYTICAL CHEMISTRY (2017)

Article Food Science & Technology

Study of kinetic parameters and development of a voltammetric sensor for the determination of butylated hydroxyanisole (BHA) in oil samples

Divya Thomas et al.

JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE (2015)

Article Polymer Science

Enhanced thermal stability of multi-walled carbon nanotubes after coating with polyaniline salt

Zuzana Moravkova et al.

POLYMER DEGRADATION AND STABILITY (2012)

Article Chemistry, Analytical

Phenol and para-substituted phenols electrochemical oxidation pathways

Teodor Adrian Enache et al.

JOURNAL OF ELECTROANALYTICAL CHEMISTRY (2011)

Article Chemistry, Multidisciplinary

Using square wave voltammetry on ultramicroelectrocles to determine synthetic antioxidants in vegetable oils

Claudio D. Ceballos et al.

JOURNAL OF CHEMICAL EDUCATION (2006)