4.6 Article

Contrast-Enhanced 3D Spin Echo T1-Weighted Sequence Outperforms 3D Gradient Echo T1-Weighted Sequence for the Detection of Multiple Sclerosis Lesions on 3.0 T Brain MRI

Journal

INVESTIGATIVE RADIOLOGY
Volume 58, Issue 5, Pages 314-319

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/RLI.0000000000000937

Keywords

brain MRI; multiple sclerosis; 3.0 T; contrast-enhanced T1

Ask authors/readers for more resources

This study compared the differences in detecting enhancing lesions between 3D TSE T1-WI and 3D GRE T1-WI in patients with multiple sclerosis (MS). The results showed that 3D TSE T1-WI detected more enhancing lesions and had higher contrast ratio and contrast-to-noise ratio. Therefore, 3D TSE T1-WI should be used in MS patients requiring contrast-enhanced examination.
Background: Using reliable contrast-enhanced T1 sequences is crucial to detect enhancing brain lesions for multiple sclerosis (MS) at the time of diagnosis and over follow-up. Contrast-enhanced 3D gradient-recalled echo (GRE) T1-weighted imaging (WI) and 3D turbo spin echo (TSE) T1-WI are both available for clinical practice and have never been compared within the context of this diagnosis. Purpose: The aim of this study was to compare contrast-enhanced 3D GRE T1-WI and 3D TSE T1-WI for the detection of enhancing lesions in the brains of MS patients. Methods: This single-center prospective study enrolled patients with MS who underwent a 3.0 T brain MRI from August 2017 to April 2021 for follow-up. Contrast-enhanced 3D GRE T1-WI and 3D TSE T1-WI were acquired in randomized order. Two independent radiologists blinded to all data reported all contrast-enhanced lesions in each sequence. Their readings were compared with a reference standard established by a third expert neuroradiologist. Interobserver agreement, contrast ratio, and contrast-to-noise ratio were calculated for both sequences. Results: A total of 158 MS patients were included (mean age, 40 +/- 11 years; 95 women). Significantly more patients had at least 1 contrast-enhanced lesion on 3D TSE T1-WI than on 3D GRE T1-WI for both readers (61/158 [38.6%] vs 48/158 [30.4%] and 60/158 [38.6%] vs 47/158 [29.7%], P < 0.001). Significantly more contrast-enhanced lesions per patient were detected on 3D TSE T1-WI (mean 2.47 vs 1.56 and 2.56 vs 1.39, respectively, P < 0.001). Interobserver agreement was excellent for both sequences, kappa = 0.96 (confidence interval [CI], 0.91-1.00) for 3D TSE T1-WI and 0.92 (CI, 0.86-0.99) for 3D GRE T1-WI. Contrast ratio and contrast-to-noise ratio were significantly higher on 3D TSE T1-WI (0.84 vs 0.53, P < 0.001, and 87.9 vs 57.8, P = 0.03, respectively). Conclusions: At 3.0 T, contrast-enhanced 3D TSE-T1-WI supports the detection of significantly more enhancing lesions than 3D GRE T1-WI and should therefore be used for MS patients requiring contrast-enhanced examination.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available