4.7 Article

Controlled mechanical and mass-transport properties of porous scaffolds through hollow strut

Journal

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijmecsci.2023.108202

Keywords

Hollow strut; Porous structure; Mechanical properties; Triply periodic minimal surface

Ask authors/readers for more resources

The rational design of bone implants is complex due to the unique combination of mechanical, mass-transport, and biological properties required for optimal performance. Conventional scaffold structures often couple important properties, making it difficult to enhance stiffness and mass-transport simultaneously. This study introduces an inner pore within the strut to achieve controlled mechanical and mass-transport properties, decoupling permeability and mechanical property to a good extent.
The rational design of bone implants is relatively complex because they should meet a unique combination of mechanical, mass-transport, and biological properties for favorable performance. However, in conventional to-pological structures of scaffolds, some important properties are coupled, which hampers the achievement of optimal performance. For example, it is difficult to enhance the stiffness and mass-transport properties of a scaffold simultaneously. This study aims to obtain controlled mechanical and mass-transport properties of scaffolds through adding an inner pore within the strut. The experimental results suggest that permeability and mechanical property were decoupled to a good extent, e.g., the elastic modulus of the four fabricated samples ranges from 1428.6 MPa to 3924.4 MPa, while the counterpart permeability distribution ranges from 11.08 x 10-9 m2 to 12.35 x 10-9 m2 (only 10% difference). Then, combination of the stiffness and permeability was controlled through porosity and inner pore. The simulated results show that permeability is sensitive to both the added inner pore and porosity while elastic modulus depends largely on the porosity, which provides a robust and straightforward approach to tailor the mechanical and mass-transport properties. The hollow-strut structure allows for greater design freedom in the combination of multi-physical properties, which provides a promising basis to the design of high-performance bone implants.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available