4.6 Article

A new hybrid islanding detection method for mini hydro-based microgrids

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.ijepes.2022.108437

Keywords

Distributed generation (DG); Islanding detection method (IDM); Microgrids; Mini -hydro; Non -detection zone (NDZ)

Ask authors/readers for more resources

This paper proposes a fast and reliable hybrid islanding detection method for mini-hydro-based distributed generations. The proposed method combines passive and active techniques to achieve zero non-detection zone. Simulation results demonstrate the superior performance, high reliability, and low computational complexity of the proposed method.
This paper proposes a fast and reliable hybrid islanding detection method (IDM) for mini-hydro-based distributed generations (DGs) with zero non-detection zone (NDZ). The proposed IDM aims to tackle the islanding events caused by a self-excited induction generator (SEIG) when it is driven by a mini-hydro turbine system utilising the transient dynamic response of the governor for the first time. To achieve such a goal, it takes advantage of a twostage process in which both passive and active techniques are combined. Thus, if the rate of change of frequency (ROCOF)-based threshold of the first stage is exceeded, the power reference of the mini-hydro unit is modified, implying a change in the turbine governor gate position. The mechanical torque applied to the prime mover is accordingly shifted to a new state so that both frequency and its derivative will exceed the established thresholds in the second stage in the islanding mode. Conversely, the effect of imposed disturbance is eminently negligible in the grid-connected mode since the frequency is strictly dictated by the main grid. The proposed IDM has been evaluated through numerous islanding and non-islanding case studies considering both single and multi-DG scenarios in MATLAB/Simulink. The outcomes highlight the outstanding performance of the proposed algorithm with zero NDZ and 473 ms average detection time, indicating the capability of the governor system as a reliable tool to identify islanding operations. The proposed technique does not degrade the power quality (PQ) of the grid, requires a low level of computational complexity and provides a high degree of reliability. Therefore, it is a robust and cost-effective solution for future microgrids with great penetration of mini-hydro units. (c) 2017 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available