This study is the first multi-user study to investigate the control and use of a multi-grip hand prosthesis at home. It found that participants demonstrated broader usage of grips in pattern recognition compared to direct control. After the home trial, participants showed significant improvements in myoelectric control using pattern recognition.
With the increasing availability of more advanced prostheses individuals with a transradial amputation can now be fit with single to multi-degree of freedom hands. Reliable and accurate control of these multi-grip hands still remains challenging. This is the first multi-user study to investigate at-home control and use of a multi-grip hand prosthesis under pattern recognition and direct control. Individuals with a transradial amputation were fitted with and trained to use an OSSUR i-Limb Ultra Revolution with Coapt COMPLETE CONTROL system. They participated in two 8-week home trials using the hand under myoelectric direct and pattern recognition control in a randomized order. While at home, participants demonstrated broader usage of grips in pattern recognition compared to direct control. After the home trial, they showed significant improvements in the Assessment of Capacity for Myoelectric Control (ACMC) outcome measure while using pattern recognition control compared to direct control; other outcome measures showed no differences between control styles. Additionally, this study provided a unique opportunity to evaluate EMG signals during home use. Offline analysis of calibration data showed that users were 81.5% [7.1] accurate across a range of three to five grips. Although EMG signal noise was identified during some calibrations, overall EMG quality was sufficient to provide users with control performance at or better than direct control.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available