Enzyme-indole Pyrazole-capped SeNPs based Electrochemical Biosensor for Sensitive Detection of Adenosine Triphosphate

Journal

CURRENT ANALYTICAL CHEMISTRY
Volume 19, Issue 4, Pages 298-308

Publisher

BENTHAM SCIENCE PUBL LTD
DOI: 10.2174/1573411019666221227090358

Keywords

Adenosine triphosphate (ATP); indole pyrazole ligand (TRPIDC-CH3); selenium nanoparticles (SeNPs); square wave voltammetry (SWV); hexokinase (Hex); glucose oxidase (GO)

Ask authors/readers for more resources

An electrochemical biosensor was developed for the indirect detection of Adenosine triphosphate (ATP) by immobilizing multiwalled carbon nanotubes decorated with pyrazole-capped selenium nanoparticles and dual enzyme reaction onto the surface of a glassy carbon electrode. The biosensor showed excellent sensitivity, stability, and reproducibility, with a detection limit of 0.015 mM and a quantification limit of 0.050 mM for ATP in spiked tablets. The success of green synthesis of the selenium nanoparticles was confirmed through various analyses.
In this study, an electrochemical biosensor for the indirect detection of Adenosine triphosphate (ATP) was developed, which was based on the immobilization of the multiwalled carbon nanotubes (MWCNTs) decorated with pyrazole-capped selenium nanoparticles (TRPIDC-CH3 SeNPs) and dual enzyme reaction (hexokinase and glucose oxidase) onto the surface of a bare glassy carbon electrode (GCE) as a working electrode. As confirmed byUltraviolet-visible spectroscopy (UV-Vis), Fourier transform infrared (FTIR) and High-resolution electron microscope (HRTEM), the TRPIDC-CH3 SeNPs successfully green synthesised using Allium sativum cloves and indole pyrazole ligand. The electrochemical study of ATP was performed using cyclic voltammetry (CV) and square wave voltammetry (SWV) techniques on a modified electrode for indirect detection of ATP where the required strong electroactive was [Fe(CN)6](3-/4-). The phosphate buffer solution (PBS; 0.1 M) was used as a supporting electrolyte at pH 7 containing 1 mM K4[Fe(CN)6]/K3[Fe(CN)6] as the redox probe operated at an average potential of 0.23 V. The electrochemical enzymic biosensor showed outstanding sensitivity, good stability, and satisfactory reproducibility with an average RSD of 2.30%. The ATP was quantifiable in spiked tablets with a limit of detection (LOD) of 0.015 mM and a limit of quantification (LOQ) of 0,050 mM.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available