4.0 Article

[18F]PSMA-1007 renal uptake parameters: Reproducibility and relationship to estimated glomerular filtration rate

Related references

Note: Only part of the references are listed.
Article Radiology, Nuclear Medicine & Medical Imaging

Renal Cortical Scarring: 68Ga-PSMA-11 PET Versus 99mTc-DMSA Scanning in a Case of Pyelonephritis

Ismet Sarikaya et al.

Summary: This study compared the images of adult patients with pyelonephritis using different radiolabeled agents for PET and scanning to evaluate their diagnostic application. The images of the second patient demonstrated renal parenchymal defects secondary to scarring in the kidney.

JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY (2022)

Editorial Material Radiology, Nuclear Medicine & Medical Imaging

Renal Infarction Imaged With [18F]Prostate-Specific Membrane Antigen-1007 PET/CT

Niloefar Ahmadi Bidakhvidi et al.

Summary: This study reported a case of multifocal renal cortical infarction after renal transplantation. The patient showed improved renal function after treatment with acetylsalicylic acid.

CLINICAL NUCLEAR MEDICINE (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

[68 Ga]Ga-FAPI uptake correlates with the state of chronic kidney disease

Patrick Conen et al.

Summary: In this retrospective study, the diagnostic value of three different radiotracers for the noninvasive prediction of kidney fibrosis was analyzed. The results showed a significant negative correlation between renal parenchymal [(68) Ga]Ga-FAPI uptake and glomerular filtration rate (GFR), highlighting the potential value of [(68) Ga]Ga-FAPI for the noninvasive evaluation of kidney fibrosis.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2022)

Review Radiology, Nuclear Medicine & Medical Imaging

SNMMI procedure standard/EANM practice guideline on pediatric [99mTc]Tc-DMSA renal cortical scintigraphy: an update

Reza Vali et al.

Summary: This article introduces the Society of Nuclear Medicine and Molecular Imaging (SNMMI) and the European Association of Nuclear Medicine (EANM), emphasizing the importance and limitations of standards/guidelines. It encourages healthcare professionals to use the knowledge in standards/guidelines flexibly based on their professional judgment and individual patient circumstances to provide appropriate nuclear medicine care.

CLINICAL AND TRANSLATIONAL IMAGING (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Dose-reduced [18F]PSMA-1007 PET is feasible for functional imaging of the renal cortex

Kristian Valind et al.

Summary: Renal [F-18]PSMA-1007 PET-CT with imaging at 2 hours post-injection provides acceptable image quality, consistent split renal uptake, and allows for reduction in administered activity. The study demonstrates feasibility of using [F-18]PSMA-1007 PET-CT for renal imaging and suggests potential for dose optimization.

EJNMMI PHYSICS (2021)

Article Urology & Nephrology

Measured and estimated glomerular filtration rate: current status and future directions

Andrew S. Levey et al.

NATURE REVIEWS NEPHROLOGY (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Optimization of [18F]PSMA-1007 PET-CT using regularized reconstruction in patients with prostate cancer

Elin Tragardh et al.

EJNMMI PHYSICS (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

F-18 labelled PSMA-1007: biodistribution, radiation dosimetry and histopathological validation of tumor lesions in prostate cancer patients

Frederik L. Giesel et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Radiation dosimetry of 68Ga-PSMA-11 (HBED-CC) and preliminary evaluation of optimal imaging timing

Ali Afshar-Oromieh et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

PSMA-Based [18F]DCFPyL PET/CT Is Superior to Conventional Imaging for Lesion Detection in Patients with Metastatic Prostate Cancer

Steven P. Rowe et al.

MOLECULAR IMAGING AND BIOLOGY (2016)

Review Medicine, General & Internal

Estimating Equations for Glomerular Filtration Rate in the Era of Creatinine Standardization A Systematic Review

Amy Earley et al.

ANNALS OF INTERNAL MEDICINE (2012)

Article Transplantation

Development and validation of GFR-estimating equations using diabetes, transplant and weight

Lesley A. Stevens et al.

NEPHROLOGY DIALYSIS TRANSPLANTATION (2010)

Article Radiology, Nuclear Medicine & Medical Imaging

Reproducibility and repeatability of differential renal function in 4-week-old piglets

Thomas H. Dissing et al.

NUCLEAR MEDICINE COMMUNICATIONS (2008)

Article Radiology, Nuclear Medicine & Medical Imaging

Inter-observer reproducibility of relative 99Tcm-DMSA uptake

M Tondeur et al.

NUCLEAR MEDICINE COMMUNICATIONS (2000)