4.3 Article

Oncology-specific radiation dose and image noise reference levels in adult abdominal-pelvic CT

Related references

Note: Only part of the references are listed.
Article Radiology, Nuclear Medicine & Medical Imaging

Reduced-Dose Deep Learning Reconstruction for Abdominal CT of Liver Metastases

Corey T. Jensen et al.

Summary: This study compared reduced-dose deep learning image reconstruction with standard-dose filtered back projection contrast-enhanced abdominal CT in evaluating liver metastases and image quality. The results showed that deep learning image reconstruction improved CT image quality while reducing radiation dose, with superior performance in detecting liver lesions larger than 0.5 cm.

RADIOLOGY (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Assessment of task-based image quality for abdominal CT protocols linked with national diagnostic reference levels

Anais Viry et al.

Summary: Task-based image quality varies among different CT scanners, especially at low dose levels. Scanner-specific dose optimization is necessary to achieve comparable image quality.

EUROPEAN RADIOLOGY (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Patient-based Performance Assessment for Pediatric Abdominal CT: An Automated Monitoring System Based on Lesion Detectability and Radiation Dose

Tyler Lacy et al.

Summary: This study utilized an automated tool to evaluate pediatric body CT performance in terms of radiation dose and image quality, revealing that younger patients generally had higher detectability index values, indicating better image quality.

ACADEMIC RADIOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Delayed bolus-tracking trigger at CT correlates with cardiac dysfunction and suboptimal portovenous contrast phase

Corey T. Jensen et al.

Summary: This study found that delayed trigger time during CT may be associated with reduced heart function and suboptimal portovenous contrast phase, indicating a potential need for adjustments in imaging protocols for patients with cardiac dysfunction.

ABDOMINAL RADIOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

CT diagnostic reference levels based on clinical indications: results of a large-scale European survey

Virginia Tsapaki et al.

Summary: This study investigated the feasibility of defining diagnostic reference levels (DRLs) based on specific clinical indications (CIs) across Europe. Data from 19 hospitals in 14 European countries were collected on 4299 adult patients, showing considerable variations in DRLs between sites for the same CI.

EUROPEAN RADIOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

A Benchmark for automatic noise measurement in clinical computed tomography

Moiz Ahmad et al.

Summary: The study benchmarks the accuracy of the global noise (GN) algorithm for automatic noise measurement in contrast-enhanced abdomen CT exams, showing high accuracy and applicability across image sets of varying noise magnitude. The GN algorithm was further optimized for automatic measurement of soft-tissue noise in abdomen CT exams.

MEDICAL PHYSICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Assessment of the global noise algorithm for automatic noise measurement in head CT examinations

Moiz Ahmad et al.

Summary: The study evaluated the accuracy of the GN algorithm in automatic noise measurement in head CT examinations, showing that the algorithm had comparable errors to reference manual measurement and could detect noise differences in different scan protocols. Additionally, the GN measurements were correlated with patient head size and could predict the CT scanner X-ray beam quality.

MEDICAL PHYSICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

CT Noise-Reduction Methods for Lower-Dose Scanning: Strengths and Weaknesses of Iterative Reconstruction Algorithms and New Techniques

Payam Mohammadinejad et al.

Summary: IR algorithms are widely used in CT imaging for noise reduction, although they may alter spatial resolution and noise texture in different regions of the image. New IR algorithms and CT noise-reduction techniques are emerging, with convolutional neural networks showing promise for reducing noise while preserving image detail. Novel CT noise-reduction methods are being developed to leverage spatial and/or spectral redundancy in multiphase or multienergy CT imaging.

RADIOGRAPHICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Correlation of Algorithmic and Visual Assessment of Lesion Detection in Clinical Images

Yuan Cheng et al.

ACADEMIC RADIOLOGY (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Quantification and homogenization of image noise between two CT scanner models

Samuel A. Einstein et al.

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Image Quality Assessment of Abdominal CT by Use of New Deep Learning Image Reconstruction: Initial Experience

Corey T. Jensen et al.

AMERICAN JOURNAL OF ROENTGENOLOGY (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Improved Computed Tomography Contrast Injection Rates Through Implantable Chest Power Ports

James C. Fielding et al.

JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY (2020)

Review Radiology, Nuclear Medicine & Medical Imaging

Diagnostic Reference Levels based on clinical indications in computed tomography: a literature review

Graciano Paulo et al.

INSIGHTS INTO IMAGING (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Detection of Colorectal Hepatic Metastases Is Superior at Standard Radiation Dose CT versus Reduced Dose CT

Corey T. Jensen et al.

RADIOLOGY (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

CT diagnostic reference levels: are they appropriately computed?

Thibault Vanaudenhove et al.

EUROPEAN RADIOLOGY (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Expanding the Concept of Diagnostic Reference Levels to Noise and Dose Reference Levels in CT

Francesco Ria et al.

AMERICAN JOURNAL OF ROENTGENOLOGY (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Validation of algorithmic CT image quality metrics with preferences of radiologists

Yuan Cheng et al.

MEDICAL PHYSICS (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

US Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations

Kalpana M. Kanal et al.

RADIOLOGY (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Updated estimates of typical effective doses for common CT examinations in the UK following the 2011 national review

Paul C. Shrimpton et al.

BRITISH JOURNAL OF RADIOLOGY (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Automated Technique to Measure Noise in Clinical CT Examinations

Olav Christianson et al.

AMERICAN JOURNAL OF ROENTGENOLOGY (2015)

Editorial Material Radiology, Nuclear Medicine & Medical Imaging

ACR Dose Index Registry

Richard L. Morin et al.

JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY (2011)