4.8 Article

Electrochemiluminescence Cascade Amplification Platform for Detection of Dual-microRNA and Operation of Concatenated Logic Circuit

Journal

ANALYTICAL CHEMISTRY
Volume 94, Issue 49, Pages 17279-17286

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.2c04242

Keywords

-

Funding

  1. National Natural Science Foundation of China
  2. [22034006]
  3. [21721003]

Ask authors/readers for more resources

In this study, an electrochemiluminescence (ECL) cascade amplification platform was constructed for dual acute myocardial infarction (AMI) related microRNA detection. The independent operation of Zn2+-dependent DNAzyme digestion reaction and DSN-assisted target recycling improved the detection efficiency of the system. The cascade amplification strategy improved the detection sensitivity for each target and the application of ECL method was extended to logic gates.
The detection of multiple biomarkers is of great significance to the accurate diagnosis of diseases. Herein, in this work, we constructed an electrochemiluminescence (ECL) cascade amplification platform for dual acute myocardial infarction (AMI)related microRNA detection. The Zn2+-dependent DNAzyme digestion reaction initiated by miR-133a and the duplex-specific nuclease (DSN) cleavage circuit initiated by miR-499 were carried out independently to form a fuel hairpin DNA and active initiator strand, respectively, to trigger a hybridization chain reaction, which constituted a two-input-regulated AND logic circuit based on single ECL signal output. The use of single signal probe (Ru(bpy)32+) avoided the time-consuming and costly process of multiple signal molecule labeling or modification. The independent operation of the DNAzyme digestion reaction and DSN-assisted target recycling improved the detection efficiency of the system. In addition, the detection of each miRNA had undergone a cascade amplification process, which improved the detection sensitivity for each target. Furthermore, benefitting from the strong complexation of EDTA with Zn2+ and the flexible design of DNA sequences, the two-input AND logic gate was extended to a four input INHIBIT-AND-INHIBIT concatenated logic circuit, which broadens the application of the ECL method in logic gates. We anticipate that this cascading amplification strategy can be widely applied in accurate diagnosis of AMI and the construction of ECLbased logic devices.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available