In this study, a novel electrochemiluminescence (ECL) immunoassay device was developed for the point-of-care testing of Alzheimer-associated neuronal thread protein (AD7c-NTP). The device allows automatic collection and analysis of ECL signals after manual addition of sample and buffer solutions onto the immunosensor. The proposed device demonstrated acceptable selectivity, stability, and reproducibility, and successfully detected AD7c-NTP levels in human urine.
In this study, we developed, for the first time, a (ECL) immunoassay device for point-of-care testing (POCT) of Alzheimer-associated neuronal thread protein (AD7c-NTP), where the ECL signals were automatically collected and analyzed after the sample and buffer solutions were manually added onto the immunosensor. The proposed immunoassay device contains an automatic ECL analyzer and a dry chemistry-based ECL immunosensor fabricated with a screen-printed fiber materialbased chip and a three-dimensional (3D)-printed shell. Each pad of the fiber material-based chip was premodified with certain reagents for immunoreaction and then assembled to form the ECL immunosensor. The self-enhanced ECL of the Ru(II)-poly-L-lysine complex and the lateral flow fiber material-based chip make the addition of coreactants and repeated flushing unnecessary. Only the sample and buffer solutions are added to the ECL immunosensor, and the process of ECL detection can be completed in about 6 min using the proposed automatic ECL analyzer. Under optimized conditions, the linear detection range for AD7c-NTP was 1 to 104 pg/mL, and the detection limit was 0.15 pg/mL. The proposed ECL immunoassay device had acceptable selectivity, stability, and reproducibility and had been successfully applied to detect AD7c-NTP levels in human urine. In addition, the accurate detection of AD7c-NTP and duplex detection of AD7c-NTP and apolipoprotein E epsilon 4 gene were also validated. It is believed that the proposed ECL immunoassay device may be a candidate for future POCT applications.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available