This study proposes a comprehensive workflow to ensure the accuracy of sequence determination in styrene-acrylate copolymers using Py-GC and 13C NMR. The results show that Py-GC consistently underestimates the acrylate sequence length, and calibration with 13C NMR is necessary for accurate absolute quantification. However, NMR calibration may not be required in all cases to obtain relative information on the sequence of a copolymer.
Many industrial polymers which find application in contemporary materials are copolymers. Copolymers feature multiple distributions, that govern their physical properties, including the sequence distribution. Styreneacrylate copolymers are an important class of polymers, their monomer sequence is typically determined by 13C NMR which suffers from low sensitivity and spectral resolution. A series of studies have shown that Py-GC can be applied to determine the sequence length of copolymers. The accuracy of the trimer assignments and the appropriate calibration approaches yielding reliable data have however not yet been validated. In the present study we propose a comprehensive workflow to ensure the accuracy of the sequence determination by Py-GC, next to NMR. In-depth analysis of the trimers observed in the Py-GC pyrograms of model styrene-acrylate copolymers was performed and specific MS fragments relating to the trimer sequence were assigned. A comparison of a series of copolymers yielded reliable assignments for the trimer signals. The obtained sequence lengths were in agreement with those calibrated with the benchmark method, 13C NMR. Py-GC was found to consistently underestimate the acrylate sequence length. Py-GC calibration with 13C NMR was thus found to be indispensable for the accurate absolute quantification of the sequence length by Py-GC. The calculated randomness did not vary significantly after NMR calibration, indicating that NMR calibration might not be required in all cases to obtain (relative) information on the sequence of a copolymer.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available