4.6 Article

Experimental investigation of a two-phase ejector installed into the refrigeration system for performance enhancement

Journal

ENERGY REPORTS
Volume 8, Issue -, Pages 7263-7273

Publisher

ELSEVIER
DOI: 10.1016/j.egyr.2022.05.236

Keywords

Two-phase ejector; Ejector-expansion refrigeration; Expansion work recovery

Categories

Funding

  1. King Mongkut's University of Technology North Bangkok, Thailand [KMUTNB-64-KNOW-28]

Ask authors/readers for more resources

In this paper, the performance enhancement of a two-phase ejector installed in an ejector-expansion refrigeration system (EERS) is experimentally investigated and compared with a conventional vapour-compression refrigeration system (VCRS). The results show that the EERS performs better than the VCRS when the expansion pressure ratio is sufficiently large. Decreasing the cooling temperature can increase the system's performance and prolong the compressor's lifespan.
In this paper, the performance enhancement of the two-phase ejector installed into the refrigeration system called an ejector-expansion refrigeration system (EERS) is investigated experimentally. A comparative performance of an ejector expansion refrigeration system (EERS) with a conventional vapour-compression refrigeration (VCRS) system is proposed. The main purpose is to demonstrate the ability to mitigate the throttling loss or to demonstrate the expansion work recovery in which the theoretical work is limited. The experimental test bench which can be operated with both VCRS and EERS is designed and built for investigations. It is designed to produce chilled water under various cooling loads which allows it to produce the desired cooling temperature for performance assessment. The condenser is cooled by the cooling water whose temperature can be controlled precisely. The test results indicate that the EERS gives better performance over the VCRS when the expansion pressure ratio must be large enough. Therefore, there is limitation of using the EERS for the expansion work recovery. The system COP can be increased by 5.3-12.7% when the cooling temperature is decreased from 12 to 2 degrees C. The pressure lift effect of the two-phase ejector causes a reduction in the compressor's pressure ratio which results in a lower specific work and the refrigerant discharge temperature. This yields a longer life-time of the compressor and better lubrication. It is also found that the working condition has a significant impact on the ability to enhance the system performance of the two-phase ejector installed into the refrigeration system. (C) 2022 The Author( s). Published by Elsevier Ltd.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available