4.7 Article

Cochlear Implantation in Obliterated Cochlea: A Retrospective Analysis and Comparison between the IES Stiff Custom-Made Device and the Split-Array and Regular Electrodes

Journal

JOURNAL OF CLINICAL MEDICINE
Volume 11, Issue 20, Pages -

Publisher

MDPI
DOI: 10.3390/jcm11206090

Keywords

inner ear; cochlear implant; obliteration of the inner ear; ossification; fibrous tissue growth; electrode impedance; insertion probe

Funding

  1. MED-EL Hannover Research Center

Ask authors/readers for more resources

Anatomical malformations, cochlear obstructions, or re-implantations present challenges in cochlear implantation, but can be treated with methods like incomplete insertion, double array implantation, and radical cochleostomy. Special cases may benefit from using a stiff electrode array to facilitate implantation. Retroactive comparison of impedance and speech perception data between different treatment methods showed that the IES CMD device had positive outcomes for patients with obliterated cochleae.
Anatomical malformations, obliterations of the cochlea, or re-implantations pose particular challenges in cochlear implantation. Treatment methods rely on radiological and intraoperative findings and include incomplete insertion, the implantation of a double array, and radical cochleostomy. In addition, a stiff electrode array, e.g., the IE stiff (IES) custom-made device (CMD, MED-EL), was prescribed individually for those special cases and pre-inserted prior to facilitate cochlear implantation in challenging cases. Data on outcomes after implantation in obliterated cochleae are usually based on individual case reports since standardised procedures are lacking. A retrospective analysis was conducted to analyse our cases on obliterated cochleae treated with MED-EL devices in order to allow the different cases to be compared. Impedances and speech perception data of patients treated with the IES CMD and the double array were retrospectively compared to patients treated with a STANDARD or FLEX electrode array (the REGULAR group). Patients with a Split-Array CMD had a poor speech perception when compared to patients treated with the IES CMD device. Thus, the IES CMD can successfully be used in patients with obliterated cochleae who would otherwise be non-users, candidates for a Split-Array CMD, or candidates for partial insertion with insufficient cochlear coverage.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available