4.5 Article

Effect of Strain on Rodent Glaucoma Models: Magnetic Bead Injection Versus Hydrogel Injection Versus Circumlimbal Suture

Journal

Publisher

ASSOC RESEARCH VISION OPHTHALMOLOGY INC
DOI: 10.1167/tvst.11.9.31

Keywords

glaucoma animal model; magnetic bead injection; hydrogel injection; circumlimbal suture; rat strain

Categories

Funding

  1. Seoul Metropolitan Government-Seoul National University Boramae Medical Center [04-2022-29]

Ask authors/readers for more resources

This study compares the inter-strain differences of three rodent glaucoma models and finds that Brown Norway rats are advantageous for the magnetic bead and hydrogel injection models, while any rat strain can be used for the circumlimbal suture model. The choice of strains should be carefully considered when establishing glaucoma models with different intraocular pressure profiles.
Purpose: To compare the inter-strain differences of three rodent glaucoma models as induced by magnetic bead injection, hydrogel injection, and circumlimbal suture. Methods: In Brown Norway (BN) and Sprague Dawley (SD) rat strains, intraocular pressure (IOP) was elevated by injection of magnetic beads or hydrogel to obstruct the aqueous humor outflow or by external compression of circumlimbal suture. Maximum and average IOP values were compared according to both procedure and rat strain over 1 month postoperatively. Retinal ganglion cell (RGC) density loss was evaluated using confocal microscopic images of the flat-mounted retina obtained at postoperative days 14 and 30. Results: The maximum IOPs were higher in the hydrogel injection or circumlimbal injection models than in the magnetic bead injection model (P < 0.001), whereas average IOP showed no difference between the two strains (both P = 0.05). A generalized estimating equation regression model showed that the IOP increase was maintained better in the BN rats than in the SD rats (P < 0.001). Such inter-strain difference was smaller in the circumlimbal suture model. A significant decrease in RGC density was observed in all of the models for the BN rats and in the circumlimbal suture model for the SD rats at postoperative day 30. Conclusions: BN rats were advantageous for the magnetic bead or hydrogel injection model, but either rat strain could be used for the circumlimbal suture model. Strains should be considered cautiously when establishing rodent glaucoma models with different IOP profiles. Translational Relevance: This comparison offers the best strain for each rodent glaucoma model for assessment of glaucoma-relevant therapeutics.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available