4.3 Article

Serum Anion Gap Level Predicts All-Cause Mortality in Septic Patients: A Retrospective Study Based on the MIMIC III Database

Journal

JOURNAL OF INTENSIVE CARE MEDICINE
Volume 38, Issue 4, Pages 349-357

Publisher

SAGE PUBLICATIONS INC
DOI: 10.1177/08850666221123483

Keywords

serum anion gap; mortality; sepsis; MIMIC III

Ask authors/readers for more resources

This study quantitatively assessed the association between serum anion gap (AG) levels and all-cause mortality among sepsis patients. The findings revealed that high serum AG levels were significantly associated with an increased risk of mortality in sepsis patients. Serum AG may serve as an alternative parameter for predicting death risk in sepsis when other variables are not immediately available.
Purpose Sepsis is a significant threat in the intensive care unit (ICU) worldwide because it has high morbidity and mortality rates. Early recognition and diagnosis of sepsis are essential for the prevention of adverse outcomes. The present study aimed to quantitatively assess the association between serum anion gap (AG) levels and 30- and 90-day all-cause mortality among sepsis patients. Methods Clinical data of patients diagnosed with sepsis were extracted from the Medical Information Mart for Intensive Care III (MIMIC III) database. Kaplan-Meier curves and Cox proportional hazards models were used to evaluate the association between serum AG levels and all-cause mortality. A receiver operating characteristic (ROC) curve was drawn to quantify the efficacy of using the serum AG level to predict all-cause mortality. Results A total of 3811 patients were included in the study. The Kaplan-Meier curves showed that patients with higher serum AG levels had a shorter survival time than those with lower levels. Serum AG levels were found to be highly effective in predicting all-cause mortality secondary to sepsis (30-day: AUROC = 0.703; 90-day: AUROC = 0.696). The Cox regression model further indicated that the serum AG level was an independent risk factor for 30- and 90-day mortality in sepsis (HR 3.44, 95% CI 2.97-3.99 for 30-day; HR 3.17, 95% CI 2.76-3.65 for 90-day, P < 0.001 for both). Conclusions High serum AG may be considered as an alternative parameter for predicting the death risk in sepsis when other variables are not immediately available. Prospective large-scale studies are needed to support its predictive value in the clinic.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available