4.7 Article

Prone positioning may increase lung overdistension in COVID-19-induced ARDS

Journal

SCIENTIFIC REPORTS
Volume 12, Issue 1, Pages -

Publisher

NATURE PORTFOLIO
DOI: 10.1038/s41598-022-20881-6

Keywords

-

Funding

  1. Technology Agency of the Czech Republic [FW 01010679]
  2. Grant Agency of the Czech Republic [GA CR 22-34020S]

Ask authors/readers for more resources

This study aimed to investigate the individualized adjustment of positive end-expiratory pressure (PEEP) and body position in mechanically ventilated patients with COVID-19-induced acute respiratory distress syndrome (ARDS) and its impact on lung collapse and overdistension. The findings suggest that prone positioning can decrease lung collapse at low PEEP levels but increase lung overdistension at high PEEP levels.
Real-time effects of changing body position and positive end-expiratory pressure (PEEP) on regional lung overdistension and collapse in individual patients remain largely unknown and not timely monitored. The aim of this study was to individualize PEEP in supine and prone body positions seeking to reduce lung collapse and overdistension in mechanically ventilated patients with coronavirus disease (COVID-19)-induced acute respiratory distress syndrome (ARDS). We hypothesized that prone positioning with bedside titrated PEEP would provide attenuation of both overdistension and collapse. In this prospective observational study, patients with COVID-19-induced ARDS under mechanical ventilation were included. We used electrical impedance tomography (EIT) with decremental PEEP titration algorithm (PEEPEIT-titration), which provides information on regional lung overdistension and collapse, along with global respiratory system compliance, to individualize PEEP and body position. PEEPEIT-titration in supine position followed by PEEPEIT-titration in prone position were performed. Immediately before each PEEPEIT-titration, the same lung recruitment maneuver was performed: 2 min of PEEP 24 cmH(2)O and driving pressure of 15 cmH(2)O. Forty-two PEEPEIT-titration were performed in ten patients (21 pairs supine and prone positions). We have found larger % of overdistension along the PEEP titration in prone than supine position (P = 0.042). A larger % of collapse along the PEEP titration was found in supine than prone position (P = 0.037). A smaller respiratory system compliance was found in prone than supine position (P < 0.0005). In patients with COVID-19-induced ARDS, prone body position, when compared with supine body position, decreased lung collapse at low PEEP levels, but increased lung overdistension at PEEP levels greater than 10 cm H2O. Trial registration number: NCT04460859.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available