This study compared the performance of synthesized mammograms (AI CAD SM) with full-field digital mammograms (DM) and digital breast tomosynthesis (DBT) images. The results showed that AI CAD SM had better diagnostic performance than DM. AI CAD SM + DBT also performed better than DM + DBT, but the difference was not statistically significant.
Background It remains unclear whether original full-field digital mammograms (DMs) can be replaced with synthesized mammograms in both screening and diagnostic settings. To compare reader performance of artificial intelligence computer-aided detection synthesized mammograms (AI CAD SMs) with that of DM alone or in combination with digital breast tomosynthesis (DBT) images in an experimental setting. Methods We compared the performance of multireader (n = 4) and reading multicase (n = 388), in 84 cancers, 83 biopsy-proven benign lesions, and 221 normal or benign cases with negative results after 1-year follow-up. Each reading was independently interpreted with four reading modes: DM, AI CAD SM, DM + DBT, and AI CAD SM + DBT. The accuracy of probability of malignancy (POM) and five-category ratings were evaluated using areas under the receiver operating characteristic curve (AUC) in the random-reader analysis. Results The mean AUC values based on POM for DM, AI CAD SM, DM + DBT, and AI CAD SM + DBT were 0.871, 0.902, 0.895, and 0.909, respectively. The mean AUC of AI CAD SM was significantly higher (P = 0.002) than that of DM. For calcification lesions, the sensitivity of SM and DM did not differ significantly (P = 0.204). The mean AUC for AI CAD SM + DBT was higher than that of DM + DBT (P = 0.082). ROC curves based on the five-category ratings showed similar proximity of the overall performance levels. Conclusions AI CAD SM alone was superior to DM alone. Also, AI CAD SM + DBT was superior to DM + DBT but not statistically significant.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available