4.7 Article

Anti-biofouling Ti3C2TX MXene-holey graphene modified electrode for dopamine sensing in complex biological fluids

Journal

TALANTA
Volume 247, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.talanta.2022.123614

Keywords

Anti-biofouling; Electrochemical sensor; MXene; Holey graphene; DA sensing

Funding

  1. National Natural Science Foundation of China [51602192]
  2. Natural Science Foundation of Special Equipment Safety Supervision Inspection Institute of Jiangsu Province [KJ (Y) 2020037]
  3. Talent Program of Shanghai University of Engineering Science [QNTD202104]
  4. Shanghai Local Universities Capacity Building Project of Science and Technology Innovation Action Program [21010501700]

Ask authors/readers for more resources

A sensor based on MXene and ERHG was fabricated, showing excellent electrochemical performance and anti-biofouling properties. It can detect dopamine in phosphate-buffer saline solution with high stability and electron transfer rate.
With the development of new methods for the medical diagnosis, electrochemical sensors have attracted increasing attention. However, biofouling on the surface of the sensor significantly decreases sensor performance, thereby limiting the application of electrochemical sensors in complex biological fluids. Given the urgent need for anti-biofouling electrodes, a sensor based on a glass carbon electrode (GCE) modified with Ti3C2TX MXene and electrochemically reduced holey graphene (ERHG) was fabricated and demonstrated to have excellent electrochemical performance and anti-biofouling properties. ERHG provides abundant surface-active sites and imparts stability by hindering the agglomeration and oxidation of MXene. Furthermore, the excellent conductivity and hydrophilicity of MXene result in a high electron transfer rate and strong hydrophilicity. The MXene-ERHG/GCE sensor can detect dopamine with a wide linear range (0.2-125 mu M) and a low detection limit of 0.044 mu M in phosphate-buffer saline solution. Importantly, the hydrophilicity of MXene-ERHG reduces nonspecific protein adsorption on the electrode surface, providing resistance to biofouling. After immersion in bovine serum albumin for 30 min, MXene-ERHG/GCE retained 85.90% of its initial peak current value, much higher than that of ERHG/GCE (17.75%). The MXene-ERHG/GCE sensor also showed good sensitivity for dopamine detection in serum and artificial cerebrospinal fluid (aCSF) containing bovine serum albumin. Moreover, MXene-ERHG/GCE exhibited excellent reproducibility and long-term stability in aCSF. The results demonstrate that MXene-ERHG/GCE has excellent anti-biofouling performance, and shows potential as an electrode material for application in biosensing.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available