4.7 Article

Miniaturized anti-interference cantilever-enhanced fiber-optic photoacoustic methane sensor

Journal

SENSORS AND ACTUATORS B-CHEMICAL
Volume 370, Issue -, Pages -

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2022.132446

Keywords

Cantilever-enhanced; Photoacoustic spectroscopy; Fiber-optic acoustic sensor; Miniaturized photoacoustic cell; Methane

Funding

  1. National Nature Science Foundation of China [61905034]
  2. Natural Science Foundation of Liaoning Province [2019-MS-054]
  3. Dalian High-level Talent Innovation Support Plan [2019RQ010]
  4. Fundamental Research Funds for the Central Universities [DUT21JC03]
  5. Science and Technology Project of State Grid [52120520005C]

Ask authors/readers for more resources

In this paper, a compact cantilever-enhanced fiber-optic photoacoustic sensor resistant to electromagnetic and ambient noise interference is proposed for all-optical passive detection of CH4 in narrow spaces and harsh environments.
To realize all-optical passive detection of CH4 in narrow spaces and harsh environments, a compact cantilever-enhanced fiber-optic photoacoustic sensor (CEFPS) resistant to electromagnetic and ambient noise interference is proposed. Through theoretical analysis and finite element simulation, a miniaturized photoacoustic cell (PAC) with diffusion holes has been designed and fabricated. The diffusion holes are used for the circulation of the gas to be measured and attenuate the external noise coupled into the PAC. The concentration information of CH4 is obtained by demodulating the vibration amplitude of the built-in cantilever generated by the photoacoustic pressure. The design of the built-in cantilever structure avoids the possibility of mechanical damage and reduces the interference of external noise in the detection of photoacoustic signals. The experimental results and the Allan-Werle deviation analysis of the CH4 signal show that the minimum detection limit (MDL) is 0.32 ppm with an integration time of 60 s. The normalized noise equivalent absorption (NNEA) coefficient is calculated as 2.44 x 10(-8) cm(-1) W/Hz(1/2). The developed CEFPS achieves performance comparable to conventional resonant photoacoustic spectroscopy CH4 detectors, although the volume is two orders of magnitude lower.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available