Assessment of the precision and reproducibility of ventricular volume, function, and mass measurements with ferumoxytol-enhanced 4D flow MRI

Journal

JOURNAL OF MAGNETIC RESONANCE IMAGING
Volume 44, Issue 2, Pages 383-392

Publisher

WILEY
DOI: 10.1002/jmri.25180

Keywords

magnetic resonance imaging; ventricular myocardium; ventricular function; 4D flow

Ask authors/readers for more resources

PurposeTo compare the precision and interobserver agreement of ventricular volume, function, and mass quantification by 3D time-resolved (4D) flow MRI relative to cine steady-state free precession (SSFP). Materials and MethodsWith Institutional Research Board approval, informed consent, and HIPAA compliance, 22 consecutive patients with congenital heart disease (CHD) (10 males, 6.44.8 years) referred for 3T ferumoxytol-enhanced cardiac MRI were prospectively recruited. Complete ventricular coverage with standard 2D short-axis cine SSFP and whole chest coverage with axial 4D flow were obtained. Two blinded radiologists independently segmented images for left ventricular (LV) and right ventricular (RV) myocardium at end systole (ES) and end diastole (ED). Statistical analysis included linear regression, analysis of variance (ANOVA), Bland-Altman (BA) analysis, and intraclass correlation (ICC). ResultsSignificant positive correlations were found between 4D flow and SSFP for ventricular volumes (r=0.808-0.972, P < 0.001), ejection fraction (EF) (r=0.900-928, P < 0.001), and mass (r=0.884-0.934, P < 0.001). BA relative limits of agreement for both ventricles were between -52% to 34% for volumes, -29% to 27% for EF, and -41% to 48% for mass, with wider limits of agreement for the RV compared to the LV. There was no significant difference between techniques with respect to mean square difference of ED-ES mass for either LV (F=2.05, P=0.159) or RV (F=0.625, P=0.434). Interobserver agreement was moderate to good with both 4D flow (ICC 0.523-0.993) and SSFP (ICC 0.619-0.982), with overlapping confidence intervals. ConclusionQuantification of ventricular volume, function, and mass can be accomplished with 4D flow MRI with precision and interobserver agreement comparable to that of cine SSFP. J. Magn. Reson. Imaging 2016;44:383-392.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available