4.8 Article

A hierarchical scheduling framework for resilience enhancement of decentralized renewable-based microgrids considering proactive actions and mobile units

Journal

RENEWABLE & SUSTAINABLE ENERGY REVIEWS
Volume 168, Issue -, Pages -

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.rser.2022.112854

Keywords

Decentralized microgrids; Renewable energy sources; Resilience enhancement; Distribution feeder reconfiguration; Mobile emergency units

Funding

  1. DTE Network + - EPSRC [EP/S032053/1]

Ask authors/readers for more resources

This paper proposes a hierarchical model to enhance the resilience of decentralized microgrids by managing network outages and reducing energy not served. Different measures are taken at different stages to respond to different operating conditions. The simulation results show that these measures can significantly decrease the energy not served, and improve the supply service level and resilience index.
Nowadays, decentralized microgrids (DC-MGs) have become a popular topic due to the effectiveness and the less complexity. In fact, DC-MGs resist to share their internal information with the distribution system operator (DSO) to protect their privacy and compete in the electricity market. Further, lack of information sharing among MGs in normal operation conditions leads to form a competitive market. However, in emergency operation conditions, it results numerous challenges in managing network outages. Therefore, this paper presents a hierarchical model consisting of three stages to enhance the resilience of DC-MGs. In all stages, the network outage management is performed considering the reported data of MGs. In the first stage, proactive actions are performed with the aim of increasing the network readiness against the upcoming windstorm. In the second stage, generation scheduling, allocation of mobile units and distribution feeder reconfiguration (DFR) are operated by DSO to minimize operating costs. In the final stage, the repair crew is allocated to minimize the energy not served (ENS). Un-certainties of load demand, wind speed and solar radiation are considered, and the effectiveness of the proposed model is investigated by integrating to the 118-bus distribution network. Finally, the results of the simulation indicate that DFR and proactive actions decrease the ENS by 19,124 kWh and 4101 kWh, respectively. Further, the sharing of information among MGs leads to a 48.16% growth in the supply service level to critical loads, and consequently a 3.47% increase in the resilience index.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available