4.6 Article Proceedings Paper

Ratiometric luminescence thermometry with different combinations of emissions from Eu3+ doped Gd2Ti2O7 nanoparticles

Journal

JOURNAL OF LUMINESCENCE
Volume 169, Issue -, Pages 534-538

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jlumin.2015.01.027

Keywords

Thermometry; Luminescence; Pyrochlores; Rare earths; Nanoparticles

Categories

Ask authors/readers for more resources

Herein, Eu3+ doped Gd2Ti2O7 nanoparticles were tested for application in ratiometric luminescence thermometry. It is shown that two combinations of emissions: one that uses two emissions of Eu3+ ions and one that uses one emission of Eu3+ ions and trap emission of Gd2Ti2O7 provide thermometry over the 303-423 K temperature range with relative sensitivities between 0.14% K-1 and 0.95% K-1. Thermometry based on two Eu3+ emissions from D-5(0) to D-5(1) levels has a higher relative sensitivity, but lower absolute sensitivity than thermometry based on one Eu3+ emission and trap emission of Gd2Ti2O7. The tested material is prepared by Pechini-type polymerized complex route and is composed of agglomerated nanoparticles of similar to 30-50 nm in size with pure-phase cubic structure (space group Fd-3m) as evidenced from electron microscopy and X-ray diffraction measurements. (C) 2015 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available