4.6 Article

Absorbed-dose-to-water measurement using alanine in ultra-high-pulse-dose-rate electron beams

Related references

Note: Only part of the references are listed.
Article Radiology, Nuclear Medicine & Medical Imaging

Ultra-high dose rate electron beams and the FLASH effect: From preclinical evidence to a new radiotherapy paradigm

Emil Schuler et al.

Summary: This article reviews the studies published after Fauvadon et al.'s seminal paper from 2014, demonstrating the robust effects of FLASH radiation therapy (RT) on normal tissue sparing in preclinical models. It points out the differences in the magnitude of the FLASH effect between experiments in different labs and proposes a new standard for beam parameter reporting and a systematic path to the clinical translation of FLASH RT.

MEDICAL PHYSICS (2022)

Article Engineering, Biomedical

Response of diamond detectors in ultra-high dose-per-pulse electron beams for dosimetry at FLASH radiotherapy

R. Kranzer et al.

Summary: This study investigates the response of microDiamond detectors and their prototypes in ultra-high DPP electron beams. It is found that commercially available microDiamond detectors have limitations in terms of linearity at ultra-high DPP, but this is not an intrinsic limitation of the detector principle. By reducing sensitivity and using low series resistance, the linear range of the detectors can be extended.

PHYSICS IN MEDICINE AND BIOLOGY (2022)

Article Engineering, Biomedical

Characterization of the PTB ultra-high pulse dose rate reference electron beam

Alexandra Bourgouin et al.

Summary: This investigation focuses on the characterization and optimization of ultra-high pulse dose rate (UHPDR) electron beam at the PTB facility in Germany. Through experimental and simulation studies, two suitable setups for delivering reference UHPDR electron beams have been identified, and the reliability of the Monte Carlo model and the potential of the diamond detector prototype have been demonstrated.

PHYSICS IN MEDICINE AND BIOLOGY (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Ion collection efficiency of ionization chambers in ultra-high dose-per-pulse electron beams

Rafael Kranzer et al.

Summary: The study investigated the ion collection efficiency of vented ionization chambers in ultra-high dose-per-pulse electron beams, evaluating the impact of chamber design and electric field strength. Experimental results showed that reducing electrode distance and increasing field strength can improve ion collection efficiency and reduce polarity effects.

MEDICAL PHYSICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Dosimetry with a clinical linac adapted to FLASH electron beams

Stanislaw Szpala et al.

Summary: Dosimetric measurements were conducted to assess a linac converted to FLASH dose rates, demonstrating the usability of Gafchromic EBT-XD film and dose rate-corrected cc13 ionization chamber. The performance of the modified linac was found adequate for FLASH radiobiological experiments, with different beam properties and dose rate dependencies observed.

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS (2021)

Review Oncology

Ultra-High Dose Rate (FLASH) Radiotherapy: Silver Bullet or Fool's Gold?

Joseph D. Wilson et al.

FRONTIERS IN ONCOLOGY (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

A comparative dosimetry study of an alanine dosimeter with a PTW PinPoint chamber at ultra-high dose rates of synchrotron radiation

Yasser S. Soliman et al.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

The European Joint Research Project UHDpulse - Metrology for advanced radiotherapy using particle beams with ultra-high pulse dose rates

Andreas Schueller et al.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2020)

Article Physics, Multidisciplinary

Calorimeter for Real-Time Dosimetry of Pulsed Ultra-High Dose Rate Electron Beams

Alexandra Bourgouin et al.

FRONTIERS IN PHYSICS (2020)

Article Oncology

Modifying a clinical linear accelerator for delivery of ultra-high dose rate irradiation

Michael Lempart et al.

RADIOTHERAPY AND ONCOLOGY (2019)

Article Multidisciplinary Sciences

Long-term neurocognitive benefits of FLASH radiotherapy driven by reduced reactive oxygen species

Pierre Montay-Gruel et al.

PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA (2019)

Article Oncology

Treatment of a first patient with FLASH-radiotherapy

Jean Bourhis et al.

RADIOTHERAPY AND ONCOLOGY (2019)

Proceedings Paper Engineering, Biomedical

The Metrological Electron Accelerator Facility (MELAF) for Research in Dosimetry for Radiotherapy

Andreas Schueller et al.

WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3 (2019)

Article Oncology

Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear Accelerator

Emil Schuler et al.

INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS (2017)

Article Instruments & Instrumentation

Traceable charge measurement of the pulses of a 27 MeV electron beam from a linear accelerator

A. Schueller et al.

JOURNAL OF INSTRUMENTATION (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

High dose-per-pulse electron beam dosimetry: Usability and dose-rate independence of EBT3 Gafchromic films

Maud Jaccard et al.

MEDICAL PHYSICS (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

High dose-per-pulse electron beam dosimetry - A model to correct for the ion recombination in the Advanced Markus ionization chamber

Kristoffer Petersson et al.

MEDICAL PHYSICS (2017)

Article Engineering, Biomedical

Difference in the relative response of the alanine dosimeter to megavoltage x-ray and electron beams

M. Anton et al.

PHYSICS IN MEDICINE AND BIOLOGY (2013)

Article Engineering, Biomedical

Relative response of alanine dosemeters for high-energy electrons determined using a Fricke primary standard

Sandor Voeroes et al.

PHYSICS IN MEDICINE AND BIOLOGY (2012)

Article Engineering, Biomedical

Uncertainties in alanine/ESR dosimetry at the Physikalisch-Technische Bundesanstalt

Mathias Anton

PHYSICS IN MEDICINE AND BIOLOGY (2006)