4.3 Article

Characterization of the carriers' multiplication in Si and SiC power devices by soft-gamma irradiation under cryostatic conditions

Journal

MICROELECTRONICS RELIABILITY
Volume 138, Issue -, Pages -

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.microrel.2022.114741

Keywords

Cryostat spectrometer; Carriers multiplication on power devices; Terrestrial cosmic radiation; Failure rate characterization for power devices; Coupled TCAD Monte Carlo simulation

Ask authors/readers for more resources

This paper introduces a cryostatic setup for non-invasive charge spectroscopy testing of Si and SiC devices. A relationship is provided to convert the multiplication factor measured at liquid nitrogen temperature to the multiplication measured at ambient temperature. A simulation scheme combining TCAD and Monte Carlo tools is proposed to predict the spectra of the collected charge and locate hotspots of the multiplication factor. The study suggests that the charge multiplication factor is correlated with the failure rate of power devices, making this technique a complementary method for assessing the Safe-Operating Area.
The characterization of the carriers' multiplication factor is a key issue for the design of robust and reliable power semiconductor devices and for the assessment of their susceptibility to terrestrial cosmic radiation induced failures. A cryostatic setup is presented to extend the applicability of non-invasive charge spectroscopy tech-niques using soft-gamma radiation from an Am241 radioactive source to a broad class of Si and SiC devices. A relationship is provided to convert the multiplication factor measured at liquid nitrogen temperature to the multiplication measured at ambient temperature. A dedicated simulation scheme is proposed that couples TCAD and Monte Carlo tools to predict the spectra of the collected charge and to locate hotspots of the multiplication factor. Finally, after highlighting the correlation between the charge multiplication factor and the failure rate of power devices submitted to terrestrial cosmic radiation, the present technique is suggested as a complementary method to assess the Safe-Operating Area.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available