4.7 Article

Co, N co-doped porous carbon-based nanozyme as an oxidase mimic for fluorescence and colorimetric biosensing of butyrylcholinesterase activity

Journal

MICROCHIMICA ACTA
Volume 189, Issue 9, Pages -

Publisher

SPRINGER WIEN
DOI: 10.1007/s00604-022-05446-8

Keywords

Metal-organic framework; Nanozyme; Carbon quantum dots; Fluorescence and colorimetric biosensing; Butyrylcholinesterase

Funding

  1. National Natural Science Foundation of China [21775052, 21575048]
  2. Science and Technology Development project of Jilin province, China [20180414013GH]

Ask authors/readers for more resources

A Co, N co-doped porous carbon-based nanozyme was successfully fabricated and applied in a fluorescence and colorimetric system for butyrylcholinesterase (BChE) sensing. The system showed excellent linear response and low detection limit for BChE activity.
A Co, N co-doped porous carbon-based nanozyme (Co-N-C nanozyme) has been fabricated Taking advantages of the excellent oxidase catalytic activity and significant stability of Co-N-C nanozyme, we propose a fluorescence and colorimetric system based on Co-N-C nanozyme and red-emitting carbon quantum dots (RCDs) for butyrylcholinesterase (BChE) sensing. As the chromogenic substrate 3,3',5,5'-tetramethylbenzidine (TMB) was catalyzed and oxidized by Co-N-C nanozyme, the generated oxTMB had a new absorption peak at 652 nm, which resulted in the significant quenching of the fluorescence of the carbon quantum dots at 610 nm. Under the catalysis of BChE, thiocholine was generated from the hydrolysis of S-butyrylthiocholine iodide (BTCh), and the as-generated thiocholine effectively inhibited the oxidation of TMB catalyzed by Co-N-C nanozyme, leading to a decrease of the absorption of oxTMB at 652 nm and effective fluorescence recovery of RCDs. By measuring the absorbance of produced oxTMB at 652 nm and the fluorescence of RCDs at 610 nm, the fluorescence and colorimetric system both exhibited an outstanding linear response to the activity of BChE in the range 0.5 to 40 U L-1, with a detection limit of 0.16 U L-1 and 0.21 U L-1, respectively. Furthermore, this established dual-channel biosensing strategy has been successfully applied to the determination of BChE in human serum samples. The present work has effectively expanded the development and application of nanozyme in biosensing.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available