4.5 Article

SNOAR: a new regression approach for the removal of ocular artifact from multi-channel electroencephalogram signals

Journal

MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING
Volume 60, Issue 12, Pages 3567-3583

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s11517-022-02692-z

Keywords

Electroencephalogram (EEG); Electrooculogram (EOG) signals; Singular spectrum analysis (SSA); Non-negative matrix factorization (NMF)

Funding

  1. Ministry of Education, Government of India
  2. Core Research Grant of the Science and Engineering Research Board (SERB), Department of Science and Technology (DST), Government of India [CRG/2021/007147]

Ask authors/readers for more resources

This study proposes a new method for removing ocular artifacts from multi-channel EEG signals using singular spectrum analysis (SSA) and non-negative matrix factorization (NMF). The results show that the proposed method achieves better performance in artifact removal compared to other existing methods.
Electroencephalogram (EEG) signals are often corrupted by undesirable sources like electrooculogram (EOG) artifacts, which have a substantial impact on the performance of EEG-based systems. This study proposes a new singular spectrum analysis (SSA)-non-negative matrix factorization (NMF)-based ocular artifact removal (SNOAR) method to suppress ocular artifacts from multi-channel EEG signals. First, SSA was used to estimate EOG artifacts using a small subset of frontal electrodes. Then, NMF was applied to decompose the estimated EOG artifacts into vertical EOG (VEOG) and horizontal EOG (HEOG) signals. Finally, a simple linear regression with estimated VEOG and HEOG signals was used to remove artifacts from multi-channel EEG signals. EEG recordings from two EEG datasets (Klados dataset and KARA ONE) were used to evaluate the efficiency of the proposed method. From the simulation results, it was observed that the proposed method achieved betters results in terms of low root-mean-square error (RMSE), low delta band energy ratio, and less power spectral density (PSD) difference between the original clean EEG signal and its filtered version of contaminated EEG signal compared to selected EOG artifact removal methods (independent component analysis (ICA), wavelet-enhanced ICA (wICA), improved wICA, and multivariate empirical mode decomposition (MEMD)).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available