4.2 Article

Gait evaluation in stroke hemiplegic patients using short physical performance battery

Journal

Publisher

ELSEVIER
DOI: 10.1016/j.jstrokecerebrovasdis.2022.106704

Keywords

Stroke; Gait; Rehabilitation; Short physical performance battery; Fall; Balance

Ask authors/readers for more resources

This study aimed to verify the predictive ability of SPPB for walking independence. By conducting physical assessments and functional independence measure cognitive evaluations in stroke patients, the researchers found that SPPB and FIM-C were factors influencing walking independence. However, using SPPB alone cannot determine walking independence, and a combined assessment with cognitive function may provide more accurate results.
Objectives: Falls can occur daily in stroke patients and appropriate independence assessments for fall prevention are required. Although previous studies evaluated the short physical performance battery (SPPB) in stroke patients, the relationship between SPPB and fall prediction and walking independence remains unclear. Therefore, we aimed to verify whether SPPB is a predictor of walking independence. Materials and methods: The present study included 105 hemiplegic stroke patients who were admitted to the rehabilitation ward and gave consent to participate. Cross-sectional physical function and functional independence measure cognitive (FIM-C) evaluation were conducted in hemiplegic stroke patients. Logistic regression analysis using the increasing variable method (likelihood ratio) was performed to extract factors for walking independence. Cutoff values were calculated for the extracted items using the receiver operating-characteristic (ROC) curve. Results: Among 86 participants included in the final analysis, 36 were independent walkers and 50 were dependent walkers. In the logistic regression analysis, SPPB and FIM-C were extracted as factors for walking independence. The cutoff value was 7 [area under the curve (AUC), 0.94; sensitivity, 0.83; specificity, 0.73)] for SPPB and 32 (AUC, 0.83; sensitivity, 0.69; specificity, 0.57) for FIM-C in ROC analysis Conclusions: SPPB and FIM-C were extracted as factors for walking independence. Although SPPB alone cannot determine independent walking, combined assessment of SPPB with cognitive function may enable more accurate determination of walking independence.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available