4.6 Article

Fabrication of platinum nanodendrites-modified ITO electrode for electrochemical detection of Pb (II)

Journal

JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS
Volume 33, Issue 35, Pages 26564-26579

Publisher

SPRINGER
DOI: 10.1007/s10854-022-09333-z

Keywords

-

Funding

  1. Ministry of Higher Education Malaysia
  2. Fundamental Research Grant Scheme [FRGS/1/2020/T K0/USM/01/1]

Ask authors/readers for more resources

In this work, a platinum nanodendrites (PtNDs)-modified indium-tin-oxide (ITO) electrode (PtNDs/ITO) is developed for detecting Pb(II) ions. The PtNDs are drop-cast on the ITO electrode with varying concentrations for optimizing the electrochemical surface area. A Nafion thin layer is coated on top of the PtNDs/ITO-modified electrode to improve stability. The optimized PtNDs concentration of 120 mg/L shows excellent electrochemical performance with high specificity, reproducibility, and repeatability for detecting Pb(II) ions.
In this work, platinum nanodendrites (PtNDs)-modified indium-tin-oxide (ITO) electrode (PtNDs/ITO) is developed for Pb(II) ions detection. PtNDs are produced by chemical reduction and drop-cast on the ITO electrode. The effect of varying PtNDs concentration (30, 50, 80,120, and 160 mg/L) to modify ITO electrodes is studied to optimize the electrochemical surface area for Pb(II) ions detection. A thin layer of Nafion is coated on top of the PtNDs/ITO-modified electrode to prevent PtNDs from leaching and enhance the mechanical robustness of the modified electrode. The properties of the as-synthesized PtNDs are characterized using X-ray diffraction (XRD) and transmission electron microscopy (TEM). The Nafion/PtNDs/ITO-modified electrodes are subjected to morphological study using field emission scanning electron microscope (FESEM) with energy-dispersive X-ray (EDX), surface analysis using X-ray photoelectron spectroscopy (XPS), and electrochemical analyses using cyclic voltammetry (CV) and differential pulse anodic stripping voltammetry (DPASV). The Nafion/PtNDs/ITO-modified electrode with optimum PtNDs concentration (120 mg/L) shows excellent electrochemical performance in detecting Pb(II) ions with a linear range of 10-100 ppb, limit of detection of 9.82 ppb, and sensitivity of 67.285 mu Appb(-1) cm(-2). The Nafion/PtNDs/ITO-modified electrode has high specificity toward Pb(II) ions and has good reproducibility and repeatability with a relative standard deviation of 0.79% and 3.88%, respectively.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available