4.6 Review

Synthetic Contrasts in Musculoskeletal MRI A Review

Related references

Note: Only part of the references are listed.
Article Radiology, Nuclear Medicine & Medical Imaging

Synthetic MRI is not yet ready for morphologic and functional assessment of patellar cartilage at 1.5 Tesla

C. Vogrig et al.

Summary: This study aimed to compare the effects of conventional and synthetic sequences on the morphologic assessment and relaxometry of patellar hyaline cartilage in 1.5T MRI. Results showed that synthetic images allowed for a 15% reduction in examination time compared to conventional images. However, synthetic images had lower diagnostic performance for chondropathy, more motion artifacts, and an overestimation of T2 values compared to conventional MRI sequences.

DIAGNOSTIC AND INTERVENTIONAL IMAGING (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

CT-like images based on T1 spoiled gradient-echo and ultra-short echo time MRI sequences for the assessment of vertebral fractures and degenerative bone changes of the spine

Benedikt J. Schwaiger et al.

Summary: The study evaluated the performance of MRI in detecting vertebral fractures and degenerative bone changes, with T1SGRE showing better reliability in detecting vertebral fractures.

EUROPEAN RADIOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

A Deep Learning System for Synthetic Knee Magnetic Resonance Imaging Is Artificial Intelligence-Based Fat-Suppressed Imaging Feasible?

Laura M. Fayad et al.

Summary: This study demonstrated the feasibility and high quality of using a deep learning system to create synthetic AFSMRI scans, with high diagnostic performance for structural abnormalities of the knee. The synthetic protocol showed similar detection rates compared to original MR sequences.

INVESTIGATIVE RADIOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

3D MRI with CT-like bone contrast - An overview of current approaches and practical clinical implementation

Le Roy Chong et al.

Summary: This article presents an overview of current 3D MRI approaches for imaging cortical bone with CT-like bone contrast, including ultrashort echo time, zero echo time, T1-weighted gradient recalled echo, susceptibility-weighted imaging, and deep learning techniques. The focus of recent research has been on improving the ability of 3D MRI to provide high-resolution images of cortical bone with CT-like bone contrast. The ability of 3D MRI to deliver cortical bone information with similar diagnostic performance to CT would simplify evaluation and obviate radiation exposure.

EUROPEAN JOURNAL OF RADIOLOGY (2021)

Review Radiology, Nuclear Medicine & Medical Imaging

Rapid Musculoskeletal MRI in 2021: Clinical Application of Advanced Accelerated Techniques

Jan Fritz et al.

Summary: This article reviews advanced acceleration techniques for rapid musculoskeletal MRI examinations, including parallel imaging, simultaneous multislice acquisition, compressed sensing-based sampling, and synthetic MRI techniques. These techniques can achieve significant time savings, with accelerated acquisitions saving 66-85% of time compared to unaccelerated acquisitions.

AMERICAN JOURNAL OF ROENTGENOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

To buy or not to buy-evaluating commercial AI solutions in radiology (the ECLAIR guidelines)

Patrick Omoumi et al.

Summary: In recent years, artificial intelligence has made significant progress in medical imaging, leading to the availability of numerous commercial AI solutions that require careful assessment before purchase. The ECLAIR guidelines proposed by authors from academia and industry offer a practical framework to help stakeholders evaluate commercial AI solutions in radiology, addressing factors such as relevance, performance, validation, usability, integration, regulatory aspects, and financial considerations.

EUROPEAN RADIOLOGY (2021)

Editorial Material Radiology, Nuclear Medicine & Medical Imaging

Automated and Radiation-Free Generation of Synthetic CT from MRI Data: Does AI Help to Cross the Finish Line?

Jan Fritz

RADIOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

MRI-based Synthetic CT in the Detection of Structural Lesions in Patients with Suspected Sacroiliitis: Comparison with MRI

Lennart B. O. Jans et al.

Summary: The study findings suggest that MRI-based synthetic CT has superior diagnostic performance in detecting structural lesions in the sacroiliac joints compared to traditional T1-weighted MRI, showing higher accuracy in the detection of erosions, sclerosis, and ankylosis.

RADIOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Differentiation between benign and malignant vertebral compression fractures using qualitative and quantitative analysis of a single fast spin echo T2-weighted Dixon sequence

Sebastien Bacher et al.

Summary: This study evaluated the diagnostic performance of a single sagittal fast spin echo (FSE) T2-weighted Dixon sequence in distinguishing between benign and malignant vertebral compression fractures (VCF) using qualitative and quantitative analyses. The results showed high diagnostic accuracy in both qualitative and quantitative assessments, with excellent interobserver agreement.

EUROPEAN RADIOLOGY (2021)

Review Radiology, Nuclear Medicine & Medical Imaging

The Value of 3 Tesla Field Strength for Musculoskeletal Magnetic Resonance Imaging

Iman Khodarahmi et al.

Summary: 3.0-T MRI systems offer higher signal-to-noise ratios and image resolution, greatly improving scan efficiency and accuracy. Despite facing challenges such as magnetic susceptibility and radio frequency energy deposition, these issues can be successfully managed. Overall, 3.0-T MRI systems provide higher value and performance compared to lower field systems.

INVESTIGATIVE RADIOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Synthetic T2-weighted images of the lumbar spine derived from an accelerated T2 mapping sequence: Comparison to conventional T2w turbo spin echo

Marcus Raudner et al.

Summary: Synthetic images derived using GRAPPATINI can be used for clinical assessment with high inter-rater and intra-rater agreements comparable to conventional T2w TSE, indicating good diagnostic performance in routine clinical practice.

MAGNETIC RESONANCE IMAGING (2021)

Review Computer Science, Artificial Intelligence

Deep Generative Adversarial Networks: Applications in Musculoskeletal Imaging

YiRang Shin et al.

Summary: This article introduces the application of deep learning techniques in musculoskeletal radiology, with a focus on the key architectures, technical background, and challenges of generative adversarial networks (GANs). By generating images with high realism, GANs have the potential to aid in faster imaging across different contrasts and modalities. In addition, key research trends and the challenges of clinical applicability are discussed.

RADIOLOGY-ARTIFICIAL INTELLIGENCE (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Deep learning-based MR-to-CT synthesis: The influence of varying gradient echo-based MR images as input channels

Mateusz C. Florkow et al.

MAGNETIC RESONANCE IN MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Accelerated MP2RAGE imaging using Cartesian phyllotaxis readout and compressed sensing reconstruction

Emilie Mussard et al.

MAGNETIC RESONANCE IN MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Deep-learned short tau inversion recovery imaging using multi-contrast MR images

Sewon Kim et al.

MAGNETIC RESONANCE IN MEDICINE (2020)

Article Clinical Neurology

Spine Computed Tomography to Magnetic Resonance Image Synthesis Using Generative Adversarial Networks : A Preliminary Study

Jung Hwan Lee et al.

JOURNAL OF KOREAN NEUROSURGICAL SOCIETY (2020)

Review Radiology, Nuclear Medicine & Medical Imaging

Magnetic resonance imaging biomarkers in musculoskeletal soft tissue tumors: Review of conventional features and focus on nonmorphologic imaging

Shivani Ahlawat et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

MRI T2 Mapping of the Knee Providing Synthetic Morphologic Images: Comparison to Conventional Turbo Spin-Echo MRI

Marion Roux et al.

RADIOLOGY (2019)

Editorial Material Radiology, Nuclear Medicine & Medical Imaging

T2 Mapping without Additional Scan Time Using Synthetic Knee MRI

Jan Fritz

RADIOLOGY (2019)

Article Computer Science, Interdisciplinary Applications

Image Synthesis in Multi-Contrast MRI With Conditional Generative Adversarial Networks

Salman U. H. Dar et al.

IEEE TRANSACTIONS ON MEDICAL IMAGING (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Three-dimensional high-resolution simultaneous quantitative mapping of the whole brain with 3D-QALAS: An accuracy and repeatability study

Shohei Fujita et al.

MAGNETIC RESONANCE IMAGING (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Rapid Radial T1 and T2 Mapping of the Hip Articular Cartilage With Magnetic Resonance Fingerprinting

Martijn A. Cloos et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Monitoring skeletal muscle chronic fatty degenerations with fast T1-mapping

Benjamin Marty et al.

EUROPEAN RADIOLOGY (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Accelerated T2 mapping combining parallel MRI and model-based reconstruction: GRAPPATINI

Tom Hilbert et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Clinical Feasibility of Synthetic Magnetic Resonance Imaging in the Diagnosis of Internal Derangements of the Knee

Jisook Yi et al.

KOREAN JOURNAL OF RADIOLOGY (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Quantitative T2 Mapping of Knee Cartilage: Comparison between the Synthetic MR Imaging and the CPMG Sequence

Seung Hyun Lee et al.

MAGNETIC RESONANCE IN MEDICAL SCIENCES (2018)

Article Clinical Neurology

Feasibility of a Synthetic MR Imaging Sequence for Spine Imaging

M. I. Vargas et al.

AMERICAN JOURNAL OF NEURORADIOLOGY (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Synthetic MRI of the Knee: Phantom Validation and Comparison with Conventional MRI

Neil M. Kumar et al.

RADIOLOGY (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Optimization of T2-weighted imaging for shoulder magnetic resonance arthrography by synthetic magnetic resonance imaging

Seung Hyun Lee et al.

ACTA RADIOLOGICA (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Role of Musculoskeletal Radiology in Modern Sports Medicine

John P. Hynes et al.

SEMINARS IN MUSCULOSKELETAL RADIOLOGY (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Feasibility of synthetic MRI in knee imaging in routine practice

Sana Boudabbous et al.

ACTA RADIOLOGICA OPEN (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Differentiation of Osteophytes and Disc Herniations in Spinal Radiculopathy Using Susceptibility-Weighted Magnetic Resonance Imaging

Yvonne Yi-Na Bender et al.

INVESTIGATIVE RADIOLOGY (2017)

Review Clinical Neurology

Quantifying fat replacement of muscle by quantitative MRI in muscular dystrophy

Jedrzej Burakiewicz et al.

JOURNAL OF NEUROLOGY (2017)

Article Engineering, Electrical & Electronic

Model-Based Reconstruction for T1 Mapping Using Single-Shot Inversion-Recovery Radial FLASH

Volkert Roeloffs et al.

INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Diagnosis of Calcific Tendonitis of the Rotator Cuff by Using Susceptibility-weighted MR Imaging

Dominik Noerenberg et al.

RADIOLOGY (2016)

Review Radiology, Nuclear Medicine & Medical Imaging

Internal Derangements of Joints-Past, Present, and Future

Reto Sutter et al.

INVESTIGATIVE RADIOLOGY (2015)

Article Radiology, Nuclear Medicine & Medical Imaging

Toward Quantifying the Prevalence, Severity, and Cost Associated With Patient Motion During Clinical MR Examinations

Jalal B. Andre et al.

JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY (2015)

Article Radiology, Nuclear Medicine & Medical Imaging

Testing for Interchangeability of Imaging Tests

Nancy A. Obuchowski et al.

ACADEMIC RADIOLOGY (2014)

Article Computer Science, Interdisciplinary Applications

Fast T2 Mapping With Improved Accuracy Using Undersampled Spin-Echo MRI and Model-Based Reconstructions With a Generating Function

Tilman J. Sumpf et al.

IEEE TRANSACTIONS ON MEDICAL IMAGING (2014)

Article Oncology

The Value of Magnetic Resonance Imaging for Radiotherapy Planning

Piet Dirix et al.

SEMINARS IN RADIATION ONCOLOGY (2014)

Article Multidisciplinary Sciences

Magnetic resonance fingerprinting

Dan Ma et al.

NATURE (2013)

Article Radiology, Nuclear Medicine & Medical Imaging

Quantitative assessment of skeletal muscle degeneration in patients with myotonic dystrophy type 1 using MRI

Bassem Hiba et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2012)

Editorial Material Radiology, Nuclear Medicine & Medical Imaging

Proton density fat-fraction: A standardized mr-based biomarker of tissue fat concentration

Scott B. Reeder et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

T2 mapping from highly undersampled data by reconstruction of principal component coefficient maps using compressed sensing

Chuan Huang et al.

MAGNETIC RESONANCE IN MEDICINE (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

FLAIR☆: A Combined MR Contrast Technique for Visualizing White Matter Lesions and Parenchymal Veins

Pascal Sati et al.

RADIOLOGY (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Model-Based Nonlinear Inverse Reconstruction for T2 Mapping Using Highly Undersampled Spin-Echo MRI

Tilman J. Sumpf et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2011)

Article Neurosciences

Mapping Human Cortical Areas In Vivo Based on Myelin Content as Revealed by T1- and T2-Weighted MRI

Matthew F. Glasser et al.

JOURNAL OF NEUROSCIENCE (2011)

Article Radiology, Nuclear Medicine & Medical Imaging

T1-Corrected Fat Quantification Using Chemical Shift-Based Water/Fat Separation: Application to Skeletal Muscle

Dimitrios C. Karampinos et al.

MAGNETIC RESONANCE IN MEDICINE (2011)

Article Radiology, Nuclear Medicine & Medical Imaging

Compressed Sensing Reconstruction for Magnetic Resonance Parameter Mapping

Mariya Doneva et al.

MAGNETIC RESONANCE IN MEDICINE (2010)

Article Computer Science, Interdisciplinary Applications

Model-Based Iterative Reconstruction for Radial Fast Spin-Echo MRI

Kai Tobias Block et al.

IEEE TRANSACTIONS ON MEDICAL IMAGING (2009)

Article Radiology, Nuclear Medicine & Medical Imaging

Gleaning Multicomponent T1 and T2 Information From Steady-State Imaging Data

Sean C. L. Deoni et al.

MAGNETIC RESONANCE IN MEDICINE (2008)

Article Radiology, Nuclear Medicine & Medical Imaging

Rapid magnetic resonance quantification on the brain: Optimization for clinical usage

J. B. M. Warnties et al.

MAGNETIC RESONANCE IN MEDICINE (2008)

Article Radiology, Nuclear Medicine & Medical Imaging

Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state

SCL Deoni et al.

MAGNETIC RESONANCE IN MEDICINE (2003)