4.7 Article

Reduced FV modelling based on CFD database and experimental validation for the thermo-fluid dynamic simulation of flue gases in horizontal fire-tubes

Journal

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijheatmasstransfer.2022.123033

Keywords

Fire-tube boilers; Head-losses modelling; Heat exchange modelling; Computational fluid dynamics; Genetic algorithm; Optimization

Ask authors/readers for more resources

This work proposes an optimized physical heat transfer correlation in smooth horizontal fire-tubes using a one-dimensional reduced Finite Volume Method. The correlation is validated over a wide range of operating conditions through experimental data and Computational Fluid Dynamics (CFD) simulations. The calibrated physical correlations provide accurate estimations of heat transfer and pressure drops with reduced computational cost.
The present work aims at proposing an optimized physical heat transfer correlation in smooth horizontal fire-tubes (applying a one-dimensional reduced Finite Volume Method -FVM), validated over a wide range of operating conditions. An experimental activity is first carried out, in which the temperature and pressure profiles of the flue gases, streaming through pipes while applying hot-water-boiler conditions, are measured. A Computational Fluid Dynamics (CFD) set-up is developed for simulating the thermophysical behaviour of the flue gases undergoing a wide range of operating conditions (replicating the conditions that these streams experience in the most common industrial boiler applications). The acquired experimental data with a detailed uncertainty analysis are employed for validating the developed CFD results. Subsequently, the reduced one-dimensional FVM physical models for estimating the heat transfer (taking into account the convective and radiative terms) and pressure drops are implemented. The most accurate models are calibrated using the results of the fluid-dynamics simulations. In this procedure, the coefficients of the standard models are optimized, employing a Multi Objective Genetic Algorithm optimization procedure (MOGA). This work demonstrates that the CFD simulations can reproduce the experimental data accurately. Furthermore, the estimations of the FVM model based on the calibrated physical correlations are in good agreement with numerical results, but with a reduced computational cost. Results indicate an improved estimation of tubes outlet temperature with respect to standard correlation ( 42 . 4% error reduction), while the estimated outlet pressure shows only a slight increase of the error with respect to the Fang correlation.(c) 2022 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available