4.6 Article

An Occupational Shoulder Exoskeleton Reduces Muscle Activity and Fatigue During Overhead Work

Related references

Note: Only part of the references are listed.
Article Computer Science, Artificial Intelligence

Improving Walking Economy With an Ankle Exoskeleton Prior to Human-in-the-Loop Optimization

Wei Wang et al.

Summary: This study investigated the effectiveness of a series of ankle exoskeleton assistance patterns on improving walking economy, and found that one assistance pattern could effectively reduce metabolic cost and soleus muscle activity during walking.

FRONTIERS IN NEUROROBOTICS (2022)

Article Engineering, Industrial

A physiological and biomechanical investigation of three passive upper-extremity exoskeletons during simulated overhead work

Eric B. Weston et al.

Summary: The study evaluated three passive upper-extremity exoskeletons compared to a control condition in a simulated occupational task. Though there was a significant reduction in tissue oxygenation with one exoskeleton, no increase in spinal loading or subjective discomfort was observed with any exoskeleton. The experimental task did not induce high levels of fatigue, and results may differ for tasks with greater demand on the shoulders.

ERGONOMICS (2022)

Article Engineering, Mechanical

Automatic synthesis of arthrokinematically compatible exoskeletons. A case study on its application on a shoulder occupational exoskeleton

Marco Rossini et al.

Summary: Synthesizing kinematically compatible structures for human anatomy and complexity is challenging, often resulting in sub-optimal solutions due to the large solution space. Existing methods require simplifications to reduce the number of solutions, limiting their usefulness for designers. A new method presented in this work overcomes these limitations by using graph and linear transformation theory, expanding applicability to 3D space and reducing symbolic calculations by 99%.

MECHANISM AND MACHINE THEORY (2021)

Article Chemistry, Analytical

Integration of 3D Printed Flexible Pressure Sensors into Physical Interfaces for Wearable Robots

Kevin Langlois et al.

Summary: This paper introduces a three-dimensional printed flexible capacitive pressure sensor that can be seamlessly integrated into wearable robotic applications, manufactured using additive manufacturing techniques. The study characterizes the sensors on a test bench before integrating them into an upper arm interface and calibrating the sensors with humans in the loop.

SENSORS (2021)

Review Engineering, Industrial

The influence of using exoskeletons during occupational tasks on acute physical stress and strain compared to no exoskeleton - A systematic review and meta-analysis

Mona Baer et al.

Summary: This systematic review and meta-analysis evaluated the effects of using an exoskeleton during occupational tasks on physical stress and strain, showing that using an exoskeleton can reduce acute physical stress and strain in the exoskeleton's target area. However, the impact on workers' health is still uncertain due to lack of long-term evaluations under real working conditions.

APPLIED ERGONOMICS (2021)

Review Orthopedics

Prevalence and incidence of work-related musculoskeletal disorders in secondary industries of 21st century Europe: a systematic review and meta-analysis

Renee Govaerts et al.

Summary: Work-related musculoskeletal disorders remain prevalent among blue collar workers during the 21st century, with the back and shoulder/neck being the most common affected areas. The food industry was frequently studied and associated with high prevalence values of WMSDs.

BMC MUSCULOSKELETAL DISORDERS (2021)

Article Engineering, Biomedical

Design and Evaluation of a Passive Cable-Driven Occupational Shoulder Exoskeleton

Marco Rossini et al.

Summary: This study introduces a new wearable shoulder exoskeleton that reduces anterior deltoid activity by 22% during the execution of overhead work. The new passive remote actuation system not only provides assistance only when needed, but also allows for a more convenient repositioning of the components, reducing the weight on the user's arm. The experiments conducted suggest that this device can effectively provide relief at the shoulder level without hindering the subject.

IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS (2021)

Article Behavioral Sciences

Social Processes: What Determines Industrial Workers' Intention to Use Exoskeletons?

Shirley A. Elprama et al.

HUMAN FACTORS (2020)

Article Engineering, Biomedical

Objective and Subjective Effects of a Passive Exoskeleton on Overhead Work

Pauline Maurice et al.

IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING (2020)

Article Automation & Control Systems

An Experimental Evaluation of the Proto-MATE: A Novel Ergonomic Upper-Limb Exoskeleton to Reduce Workers' Physical Strain

Ilaria Pacifico et al.

IEEE ROBOTICS & AUTOMATION MAGAZINE (2020)

Article Engineering, Industrial

Ergonomics assessment of passive upper-limb exoskeletons in an automotive assembly plant

Sofia Iranzo et al.

APPLIED ERGONOMICS (2020)

Article Rehabilitation

Design and Experimental Evaluation of a Semi-Passive Upper-Limb Exoskeleton for Workers With Motorized Tuning of Assistance

Lorenzo Grazi et al.

IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING (2020)

Article Multidisciplinary Sciences

Low-profile elastic exosuit reduces back muscle fatigue

Erik P. Lamers et al.

SCIENTIFIC REPORTS (2020)

Review Environmental Sciences

The Effects of Upper-Body Exoskeletons on Human Metabolic Cost and Thermal Response during Work Tasks-A Systematic Review

Simona Del Ferraro et al.

INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH (2020)

Review Robotics

A Review on Design of Upper Limb Exoskeletons

Muhammad Ahsan Gull et al.

ROBOTICS (2020)

Article Engineering, Industrial

The effect of a passive trunk exoskeleton on metabolic costs during lifting and walking

S. J. Baltrusch et al.

ERGONOMICS (2019)

Article Chemistry, Multidisciplinary

Squat Lifting Imposes Higher Peak Joint and Muscle Loading Compared to Stoop Lifting

Arthur van der Have et al.

APPLIED SCIENCES-BASEL (2019)

Article Environmental Sciences

Biomechanical and Metabolic Effectiveness of an Industrial Exoskeleton for Overhead Work

Thomas Schmalz et al.

INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH (2019)

Review Ergonomics

Considerations for Industrial Use: A Systematic Review of the Impact of Active and Passive Upper Limb Exoskeletons on Physical Exposures

Tasha McFarland et al.

IISE TRANSACTIONS ON OCCUPATIONAL ERGONOMICS & HUMAN FACTORS (2019)

Proceedings Paper Computer Science, Cybernetics

Industrial Exoskeleton Technology: Classification, Structural Analysis, and Structural Complexity Indicator

A. Voilque et al.

2019 WEARABLE ROBOTICS ASSOCIATION CONFERENCE (WEARRACON) (2019)

Article Ergonomics

The Amount of Support Provided by a Passive Arm Support Exoskeleton in a Range of Elevated Arm Postures

Aijse de Vries et al.

IISE TRANSACTIONS ON OCCUPATIONAL ERGONOMICS & HUMAN FACTORS (2019)

Article Ergonomics

Subjective Evaluation of a Passive Industrial Exoskeleton for Lower-back Support: A Field Study in the Automotive Sector

Ralph Hensel et al.

IISE TRANSACTIONS ON OCCUPATIONAL ERGONOMICS & HUMAN FACTORS (2019)

Article Ergonomics

Experimental Evaluation of a Shoulder-Support Exoskeleton for Overhead Work: Influences of Peak Torque Amplitude, Task, and Tool Mass

Logan Van Engelhoven et al.

IISE TRANSACTIONS ON OCCUPATIONAL ERGONOMICS & HUMAN FACTORS (2019)

Article Engineering, Industrial

The effect of a passive trunk exoskeleton on functional performance in healthy individuals

S. J. Baltrusch et al.

APPLIED ERGONOMICS (2018)

Article Engineering, Industrial

Physiological consequences of using an upper limb exoskeleton during manual handling tasks

Jean Theurel et al.

APPLIED ERGONOMICS (2018)

Article Engineering, Industrial

Evaluation of a passive exoskeleton for static upper limb activities

Kirsten Huysamen et al.

APPLIED ERGONOMICS (2018)

Article Engineering, Industrial

Assessment of an active industrial exoskeleton to aid dynamic lifting and lowering manual handling tasks

Kirsten Huysamen et al.

APPLIED ERGONOMICS (2018)

Article Engineering, Biomedical

Physical human-robot interaction of an active pelvis orthosis: toward ergonomic assessment of wearable robots

Nicolo d'Elia et al.

JOURNAL OF NEUROENGINEERING AND REHABILITATION (2017)

Article Multidisciplinary Sciences

Human-in-the-loop optimization of exoskeleton assistance during walking

Juanjuan Zhang et al.

SCIENCE (2017)

Article Engineering, Industrial

Exoskeletons for industrial application and their potential effects on physical work load

Michiel P. de Looze et al.

ERGONOMICS (2016)

Article Engineering, Biomedical

Running With an Elastic Lower Limb Exoskeleton

Michael S. Cherry et al.

JOURNAL OF APPLIED BIOMECHANICS (2016)

Article Rheumatology

Shoulder disorders and occupation

Catherine H. Linaker et al.

BEST PRACTICE & RESEARCH IN CLINICAL RHEUMATOLOGY (2015)

Article Engineering, Industrial

Ergonomic evaluation of a wearable assistive device for overhead work

Ehsan Rashedi et al.

ERGONOMICS (2014)

Article Biophysics

Vector field statistical analysis of kinematic and force trajectories

Todd C. Pataky et al.

JOURNAL OF BIOMECHANICS (2013)

Article Computer Science, Interdisciplinary Applications

One-dimensional statistical parametric mapping in Python

Todd C. Pataky

COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING (2012)

Article Sport Sciences

On analysing and interpreting variability in motor output

Paul S. Glazier et al.

JOURNAL OF SCIENCE AND MEDICINE IN SPORT (2009)

Article Computer Science, Cybernetics

An empirical evaluation of the System Usability Scale

Aaron Bangor et al.

INTERNATIONAL JOURNAL OF HUMAN-COMPUTER INTERACTION (2008)

Article Neurosciences

Assessment of low back muscle fatigue by surface EMG signal analysis: methodological aspects

D Farina et al.

JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY (2003)

Article Neurosciences

Development of recommendations for SEMG sensors and sensor placement procedures

HJ Hermens et al.

JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY (2000)